Cal Spas LTR20101058 manual NewYour SpaPortable, Preparing a Good Foundation, ForPreparing

Page 6

4

NewYour SpaPortable

Preparing a Good Foundation

Damage caused by inadequate or improper foundation support is not covered by the war- ranty..

It is the responsibility of the spa owner to provide a proper foundation for the spa.

We strongly recommended that you have a qualified, licensed contractor prepare the foundation for your spa.

Place the spa on a level concrete slab not less than 3” / 8 cm thick. If you are installing the spa indoors, pay close attention to the flooring beneath it. Choose flooring that will not be damaged or stained.

If you are installing your spa on an elevated wood deck or other structure, consult a structural engineer or a contractor to ensure the structure will support the weight of 150 pounds per square foot.

forPreparing

Electrical Installation

This product is a cord-connected spa with a pump heater, lighting fixture, and spa side control. The operating power is 110V AC.

A licensed electrician may be required to upgrade your standard receptacle and/or circuit breaker. Always follow applicable local, state and federal codes and guidelines.

The spa is equipped with a 15 amp GFCI cord and plug kit.

Plug the spa into a dedicated electrical line with a 15 amp breaker.

Always use a weatherproof-covered receptacle. Re- ceptacle shall be located not less than 5 feet (1.5

m)from and not exceeding 10 feet (3.0 m) from the inside wall of the spa (NEC 680.43(A)).

Do not use extension cords. Using an extension cord will void your warranty.

Do not bury the power cord. If your cord becomes damaged, replace it before next usage.

If you need to replace your cord, replace it with a 15 amp GFCI connection. The cord may not be longer than 15 feet (4.6 m).

Testing the GFCI

Test the GFCI plug prior to first use and periodically when the spa is powered. To test the GFCI plug ver- sion, follow these instructions. (Spa should already be plugged in and operational.)

1.Press the TEST button on the GFCI. The GFCI will trip and the spa will stop operating.

2.Press the RESET button on the GFCI. The GFCI will reset and the spa will turn back on.

The spa is now safe to use.

If the GFCI trips while the spa is in use, press the RESET button. If the GFCI does not reset, unplug the spa and call your local Cal Spas dealer for service. DO NOT USE THE SPA!

2010 Genesis Portable Spa

www.calspas.com

LTR20101058, Rev. B

Image 6
Contents LTR20101058, Rev. B 9/20/10 Operating Your Spa Cleaning and MaintenancePreparing for Your New Portable Spa Clear Water PlanImportant Safety Instructions This FirstRead First!This Preparing for Your New Portable Spa Planning the Best LocationForYour New Portable Spa NewYour SpaPortable Electrical InstallationTesting the Gfci Preparing a Good FoundationFilling and Powering Up Your Portable Spa Your New Portable SpaOperating Your Spa Operating SpaYourElectronic Control Operation Setting Filtration Cycles SpaAutomatic Time outs On display Diagnostic MessagesMessage Meaning Action Required No message DrYSnb Message Meaning Action RequiredSnA SnSJets LED Light OperationKey to Clear Water Contents of this sectionClear Water Plan Clear Water PlanBalancing the Total Alkalinity Testing and Adjusting Spa WaterClear PlanWater Balancing the pHUsing Chlorine as a Sanitizer Using Bromine as a SanitizerSanitation Chemical Safety Shocking the WaterCleaning the Filter Cleaning the Filter BasketBather Load Plan Starting the Spa with Fresh WaterClear Water Maintenance Schedule Troubleshooting Water Clarity Problems Problem Probable Causes Possible SolutionsDo not run the spa with the access panel removed Cleaning and MaintenanceRemoving the Access Panel Draining Your Portable SpaWinterizing Cold Climate Draining Cleaning and MaintenanceInstalling Cover Latches Freeze damage is not covered by your war- rantyVinyl and Leather Cleaner Cleaning and Replacing the FilterCleaning the Cover Periodic MaintenancePrior to Spa Start-Up and Refilling Cleaning the ShellAll-Purpose Cleaner Spa Finish Cleaning Fast Sheen Spa Finish Protecting WaxReplacement Parts AppendixWarranty Customer Service DisclaimersLegal Remedies Cal Spas Chemicals LTR20091058, Rev. B LTR20091058, Rev. B Genesis Portable Spa LMS Customer Service Department Locating the product serial number