Connecting Plumbing to Remote Equipment

Connecting the plumbing from the spa to the equip- ment pack must be performed in accordance to local and city codes.

NOTE: Most codes require plumbing to be rigid PVC schedule 40 or heavier in both above and below ground installations. In most cases, the use of flexible PVC plumbing is acceptable when properly buried in trenches.

Most water plumbing lines are 2” or larger and must be schedule 40 or heavier PVC. When plumbing, mini- mize the use of 90˚ elbows as much as possible. The use of 45 ˚ elbows will increase the amount of jet pressure you will have over the use of 90˚ elbows.

The plumbing on the spa shell is labeled by the factory in the following manner:

Pump 1 Suction: 2” line that connects the spa filter and bottom drain assembly to the front of pump 1.

Pump 1 Return: 2” line that connects the top of pump 1, through the equipment filter and heater back to selected jets in the spa.

Pump 2 Suction: 2” line that connects the spa filter and bottom drain assembly to the front of pump 2.

Pump 2 Return: 2” line that connects the top of pump 2 back to selected jets in the spa.

Ozone Line: 1” line that connects to a 1” flexible line extending off the bottom of the equipment pack filter canister through an ozone injector (If ozone equipped) and connected to ozone port on the spa.

Air Blower: 1 1/2” line that is plumbed out of the air blower (located on the equipment pack) and extended up 18” above the spas water level to prevent water flooding the air blower.

Air Venturi: 1/2” line that is plumbed 18” above the spa’s water level.

Topside Control Panel and Temp Sensor: 1” line that connects to the bottom of the control box located on the equipment pack.

2009 Inground Spas

Electrical and Electronic Con- nection

Remote Equipment Topside Control Panel

The next few steps to complete the installation should be performed along with installation of the tempera- ture sensor and 12V spa light wiring (if applicable). All of these components are generally installed using the same conduit.

1.Locate the topside control panel extension loom in the control box mounted with the equipment pack. This extension loom and attached black ter- minal connector (see figure at right) will be used to connect the topside control panel to the control box.

2.Connect one end of the black terminal connector to the topside control panel cable.

3.Connect the other end of the terminal connector to the extension loom.

NOTE: This connection must be kept dry. We recom- mend that a waterproof junction box be used in instal- lations where moisture could penetrate this terminal connector.

4.Lay out the extension loom to verify that you have enough length to reach the control box. Remem- ber that conduit runs are not generally run in a straight line. Every bend, and up and down run consumes line length. Take this into consideration when verifying electrical and plumbing runs.

5.Connect the extension loom to the control panel location on the circuit board located inside the control box. You will also need to connect both the temperature and high limit sensors to the cir- cuit board prior to testing. (See the temperature and high limit installation instruction on the next page for proper identification and see the wiring diagram on the inside cover of the control box for proper placement.)

6.Turn on the power supply to the spa equipment and briefly test all functions on the topside control panel to verify that both connections and exten- sion loom are in working order before proceeding with the installation.

NOTE: Circuit board programming will not allow spa operation without both the temperature and high limit sensors being properly connected to the circuit board.

13 Preparingfor

Your New Inground Spa

LTR20091002, Rev. B

www.calspas.com

Image 13
Contents LTR20091002, Rev. B 1/30/09 Preparing for Your New Inground Spa Clear Water Plan Cleaning and MaintenanceElectronic Control Operation AppendixRead This First Important Safety InstructionsHyperthermia Danger Preparing for Your New Inground Spa Inground Spa Installation ChecklistInground Spa ForYour NewPreparing forYour New Planning the Best Place for the Outdoor Equipment PackInground Spa Site Preparation SpaTesting the Gfci Breaker Gfci and Wiring RequirementsElectrical Requirements US and Canada ForYour New IngroundYour New Inground Spa Gfci Wiring DiagramRCD and Wiring Requirements Electrical Installation -- EuropeTesting the RCD Breaker Preparing forYour New IngroundRCD Wiring Diagram Preparing forYour New Inground Spa Installing the Inground ShellEquipment Pack Plumbing Connections Designer Spa SpecificationsPlumbing Connections Identifying Plumbing LinesWater Test Air TestGate/Slice Valves Electrical and Electronic Con- nection Connecting Plumbing to Remote EquipmentRemote Equipment Topside Control Panel See figure below Inground Spa Light Installation In- structionsYour New Inground Spa Pouring the Deck Your Spa Electronic Control OperationOperating SpaYour Message Frequency Action Required RPH Periodic Reminder MessagesRSA RCLMessage Meaning Action Required No message Diagnostic MessagesOn display DrySnb Sns Message Meaning Action RequiredStby Diverter Knobs Adjustable JetsWaterfalls Air VenturisClear Water Plan Contents of this sectionKey to Clear Water Clear Water PlanClear PlanWater Testing and Adjusting Spa WaterBalancing the Total Alkalinity Balancing the pHUsing Bromine as a Sanitizer Using Chlorine as a SanitizerSanitation Adding Sanitizer Tablets to the Chemical ChamberShocking the Water Chemical SafetyBather Load Filter CleaningStarting the Spa with Fresh Water PlanClear Water Maintenance Schedule Start Up Del Zone Eclipse OzonatorDay One Monday Day Two FridayProblem Probable Causes Possible Solutions Troubleshooting Water Clarity ProblemsRemoving and Reseating the Pillows Cleaning and MaintenanceSpa Cover Draining Your Spa Cleaning and Replacing the FilterWinterizing Cold Climate Draining Cleaning Cleaning the Cover, Shell and PillowsFast Sheen Spa finish protecting wax Appendix Replacement PartsFitness Series Exercise Program Keeping Fit with your Cal SpaConnecting the Exercise Equipment Cal Spas Chemicals LTR20091002, Rev. B 1/30/09

Inground Spas specifications

Cal Spas Inground Spas represent the pinnacle of luxury outdoor relaxation, seamlessly blending aesthetic appeal with cutting-edge technology. These spas are designed for avid spa enthusiasts who appreciate the benefits of hydrotherapy and socializing in an inviting environment. Crafted with premium materials, Cal Spas ensures durability and longevity, making them an investment that enhances any outdoor living space.

One of the standout features of Cal Spas Inground Spas is their customizable design. Clients can choose from a variety of dimensions, shapes, and layouts to fit their particular yard space and personal tastes. Whether opting for a sleek contemporary style or a classic design, each spa can be tailored to create a harmonious outdoor oasis. The versatility of these spas allows for various configurations, integrating seamlessly with landscaping, patios, or even decking.

In terms of technology, Cal Spas incorporates state-of-the-art hydrotherapy systems that provide personalized wellness benefits. The spa jets are strategically placed to target specific muscle groups, ensuring an invigorating and relaxing experience. With options for adjustable jets, users can customize the intensity of their massage, further enhancing the therapeutic effects. Additionally, many models come equipped with energy-efficient heating systems, allowing users to enjoy a warm soak without significant hikes in utility bills.

The integration of smart technology sets Cal Spas apart from its competitors. With optional Wi-Fi connectivity, users can control their spa remotely through a mobile app. This feature enables easy temperature adjustments, scheduling filtration cycles, and even turning the lights on or off, all at the user's fingertips. The LED lighting options not only aid in creating a serene ambiance but also enhance safety during nighttime use.

Moreover, Cal Spas ensures user comfort and safety with ergonomic seating designed to accommodate various body types while optimizing relaxation. The non-slip surfaces and advanced water purification systems further enhance user experience, prioritizing health and security.

In summary, Cal Spas Inground Spas are meticulously designed to provide an unparalleled outdoor spa experience. With their customizable designs, advanced hydrotherapy features, smart technology integration, and a commitment to user comfort, these spas are perfect for anyone looking to create a luxurious retreat in their own backyard. Whether seeking a place to unwind after a long day or entertain friends and family, Cal Spas delivers an exceptional spa experience that stands the test of time.