Heart & Home Collectables GFK-210 manual Introduction, Check Contents of Shipping Carton

Page 1

GFK-210 Blower System

- Installation and Operating Instructions -

1.0 INTRODUCTION

The GFK-210 Blower System has been designed to circu- late room air through the fireplace to enhance heat output. The GFK-210 blower system operates on 120 VAC, 60 Hz power. This is available through a receptacle in the factory installed power cord assembly. The power cord is located in the controls compartment of the fireplace.

A variable speed control is provided with the blower system to provide quiet forced air flow at the desired speeds. A temperature sensor switch, which automatically turns the blower ON/OFF, is also provided with this kit.

This blower is carefully engineered and must be installed only as specified. If you modify it or any of its components, you may cause a fire hazard and will void the WARRANTY. In addition, such action may void the coverage provided by the owner's home insurance.

CAUTION: All wiring should be done by a qualified electri- cian and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA NO. 70-current (in the United States), or with the current CSA C22.1 Canadian Electric Code (in Canada).

CAUTION! DO NOT connect 110-120 VAC wiring to the gas control valve of the fireplace.

NOTICE: The variable speed control and temperature

WARNING! Risk of Shock! Turn electrical power off at

sensor switch are not used with some remote control

the circuit breaker before beginning this installation.

systems.

 

2.0 CHECK CONTENTS OF SHIPPING CARTON

Compare CONTENTS OF CARTON in Figure 1 with the actual parts received. If any parts are missing or damaged, contact your dealer before starting installation. Do not install a damaged blower kit.

4.0 INSTALLING THE BLOWER (Metal Inserts)

1.

Remove factory-installed blower brackets by removing

 

four screws. Brackets are only used for the FireBrick

 

inserts. See Figure 2.

2.

Remove appliance from wall.

3.

Remove access panel by removing four screws. See

 

Figure 3.

4.

Screw blowers to access panel on rear of insert with

 

four screws. See Figure 4.

5.

Plug the blower cord into the blower receptacle. Con-

 

nect the white, black, and green spade connectors

 

from blower cord harness to each blower. See Figure

 

1 and Figure 6.

CONTROL

WING

NUT

060-872

BLOWER CORD

2206-068

TEMPERATURE

SENSOR

SWITCH

6.

Bundle and zip tie any wires to keep them from contact-

 

ing the fan blades. See Figure 6, Detail A.

7.

Reinstall access panel.

NOTE: Install the blower using the access panel located on the back side of the appliance.

KNOB

100-512

CONTROL

NUT

060-814

046-018A

VARIABLE SPEED CONTROL

2206-800

Figure 1

3.0 INSTALLATION PRECAUTIONS

The GFK-210 Blower Kit is tested and safe when installed in accordance with this installation manual. It is your responsi- bility to read all instructions before starting installation and to follow these instructions carefully during installation to assure maximum benefit from, and safe operation of, the blower.

Figure 2 Remove Blower Brackets

Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11

1

Image 1
Contents Installation Precautions Check Contents of Shipping CartonIntroduction Remove Access Cover Replacement Parts and Customer MaintenanceService Detail a ZIP TiesOutlet Blower Plug 120V ExistingSpeed Control RheostatRemove Access Panel Installing the Blower FireBrick InsertsFan Wiring Diagram FireBrick Inserts