5.0INSTALLING THE VARIABLE SPEED CONTROL AND TEMPERATURE SENSOR SWITCH

If using a remote control system that utilizes a blower (fan) control, disregard steps 1-3 and follow remote con- trol installation instructions.

NOTICE! The sensor switch and rheostat are not used if the blower is controlled with the RC300 remote control.

1.Remove the knob and locknut from the variable speed control. Slide the variable speed control behind the control panel. With the stem sticking out of the pre- punched hole, attach the locknut tightly and reattach the knob on the stem. See Figure 4. Turn the speed control switch to the "ON" position.

2.Slide the temperature sensor switch onto the blower stud located on the bottom of the combustion box. See Figure 3. Secure the temperature sensor switch with the wing nut provided.

NOTICE: The blower stud is located on the bottom of the combustion box. See Figure 5.

NOTICE: The temperature sensor switch must be installed so that the sensor switch is facing the combustion box surface. See Detail A of Figure 5.

3. Connect the variable speed control and the temperature

6.0RECOMMENDED OPERATING PROCE- DURES WHEN VARIABLE SPEED CONTROL AND TEMPERATURE SENSOR SWITCH ARE USED

Ignite the fire in the fireplace with the variable speed control switch in an "ON" position. The fan will automatically turn on when the temperature sensor switch closes at approxi- mately 110O F. Heated air will be delivered at the outlet grille. The fan will continue to operate after the fireplace is turned OFF until the temperature sensor switch opens.

NOTICE! During operation, ensure that all wiring is kept away from the blower wheel (fan blades).

Various conditions (such as fireplace model, type of fire- place installation, outside air temperature vs. inside air temperature) can contribute to the length of the time the blower remains on after the fireplace is turned OFF. The blower can be turned off manually with the speed control switch.

WARNING! Risk of Injury! DO NOT contact the blower wheel (fan blades) during operation.

7.0 MAINTENANCE

Periodically check the fireplace and remove any dust, dirt or obstructions.

 

sensor switch to the power cord. See Figure 6.

8.0 REPLACEMENT PARTS AND CUSTOMER

4.

Gather the loose wires underneath the appliance and

SERVICE

 

use the zip ties to restrain them and keep them away

Replacement parts and service may be obtained through

 

from the blower wheel (fan blades). See Figure 6,

 

your dealer.

 

Detail A.

 

 

 

Hardware Bag: SRV107-570A

5.

Turn the 110-120 VAC service "ON" at the circuit

breaker.

 

 

VARIABLE

 

 

SPEED

TEMPERATURE

CONTROL

SENSOR

 

 

SWITCH

BLOWER

 

 

STUD

DETAIL A

 

 

COMBUSTION BOX SURFACE

 

 

BLOWER STUD

 

 

TEMPERATURE SENSOR SWITCH

 

 

Figure 5

Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11

3

Image 3
Contents Check Contents of Shipping Carton Installation PrecautionsIntroduction Remove Access Cover Maintenance Replacement Parts and CustomerService Detail a ZIP TiesRheostat Blower Plug 120V ExistingOutlet Speed ControlRemove Access Panel Installing the Blower FireBrick InsertsFan Wiring Diagram FireBrick Inserts