1. Manuals
  2. Brands
  3. Household Appliance
  4. Air Conditioner
  5. Samsung
  6. Household Appliance
  7. Air Conditioner

Samsung Q9000 ميموري AF28HVSDADFNMG AF28HVSDADFNMG Drilling a hole and fixing the indoor unit, Connecting pipes

1 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
Download on canonical page 54 pages, 0 b

Drilling a hole and fixing the indoor unit

ffDrill a hole with diameter of 60~65mm towards the outside.

fIfthe indoor unit is installed on unstable ground, it may shake by external force or by children and get knocked down. To prevent these accidents, you must fix the top or back of the indoor unit tightly with fixing brackets.

200mm

ø60~65mm

150mm or less

Connecting pipes

• When installing, make sure there is no leakage. When recovering the refrigerant, stop the compressor first

WARNING before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant

cycle abnormally high. It may cause explosion and injury.

Installation procedure

1.Slightly hit the hole, for piping connection, with your hands or hammer.

410mm

200mm

 

 

Upper hole for drain hose

Hole for piping

connection Drain hose

Piping

42

사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_04773A-00.indd 42

2014-09-11 오후 1:16:15

MENU

Models

Contents