Samsung Q9000 ميموري AF28HVSDADFNMG AF28HVSDADFNMG Electrical work

1 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
Download on canonical page 54 pages, 0 b

Electrical work

 

The electrical work should be performed by a specialist qualified for the work.

 

CAUTION

Avoid using multi-concent but use rate power supply for air conditioner. (Use separate power cable for outdoor

 

 

unit.)

Wiring standard

ffAlways make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

ffMake sure to install exclusive power supply(purchase separately).

-- If you use multiple connecting, there is a risk of electric shock or fire.

fIfthe outdoor power supply has been selected, install circuit breaker (ELCB). (Purchased separately) ffMake sure to connect earth wire.

Type

 

Indoor unit

Indoor power (Indoor/outdoor unit power cable)

 

Outdoor unit

Outdoor power (Earth leakage circuit breaker)

 

 

 

Power

1Ph, 220~240V, 50Hz/60Hz

 

Circuit breaker

20A

Indoor/outdoor unit power cable

1.0mm2 or more

Outdoor unit power cable

2.5mm2 or more

Indoor/outdoor unit communication cable

0.75mm2 or more

Connecting procedure

1.After loosening the 4 screws() of support-inlet, disassemble the support-inlet.

2.Connect the housings of communication cable() for an indoor unit and outdoor unit.

3.Fix the power connection cable and communication cable with a cable clamp.

4.After assembling the SUPPORT-INLET and fix it with the screws().

Screw

 

Power terminal

SUPPORT-

Earth plate

INLET

Cable clamp

 

 

COVER-PCB

 

Communication

 

cable

 

Power connection

 

cable

 

Housing

46

사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_04773A-00.indd 46