Samsung SNC-C6225P, SNC-C7225P installation, INSTALLATION USING SURFACE MOUNT ON THE CEILING, ❖RS-485Termination Resistor, SNC-C6225, ❖SNC-C6225, Pin 8 is used for ON/OFF of

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 76
Download on canonical page 76 pages, 0 b

installation

RS-485 Termination Resistor

￿ON ON

1 2 3 4 5 6 7 8

Pin 8 is used for ON/OFF of RS-485 Termination. Normally, it must be OFF state. Especially when you have trouble with long Daisy chain style connection, turn ON this termination switch of last camera.

– Pin 8 : RS-485 Termination Resistor (ON/OFF)

INSTALLATION USING SURFACE MOUNT ON THE CEILING

SNC-C6225

1.To pass cables to upside of ceiling, please, make about ø60mm hole on the ceiling panel.

2.Screw surface mount bracket to ceiling with 4 screws.

3.Wire cables to terminal block and connect the terminal blocks to main unit.

4.Screw main unit to surface mount bracket with 4 lock-up screws.

5.Detach protection vinyl from dome cover.