DKS Enterprises 1838 manuals
Computer Equipment > Computer Accessories
When we buy new device such as DKS Enterprises 1838 we often through away most of the documentation but the warranty.
Very often issues with DKS Enterprises 1838 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Computer Accessories DKS Enterprises 1838 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Computer Accessories on our side using links below.
DKS Enterprises 1838 Owner Manual
49 pages 608.12 Kb
Owners Manual 1838 PC Programmable Multi-Door Access Controller 3 Use this manual with the following models only. 9 SECTION 1 - INSTALLATION 13 SECTION 2 WIRING 15 2.2 TERMINAL DESCRIPTIONS 16 2.3 WIRING DETAIL 2.3.1 Controller Only Auxiliary Terminals 1834 controller. system. Use a separate UL listed power supply. NOTES: Relay 0 is not available on the 1834 or 1838 controller. 1833, 1834, 1835, 1837, 1838 CONTROLLERMain Terminal 30 Series Controller Detail WiringSee Dwg No. M1835-065-5 for detail. 16 Volt, 20 VA UL Listed Transformer. Battery Backup - separate batteries required for phone system and weigand terminals. See Elevator Control Board Manual 2348-065 for detail. elevator control and weigand inputs will not function. Card reader connected to these terminals will operate Relay 1 Card reader connected to these terminals will operate Relay 2 Relay 2 contact is set N.O or N.C. with a jumper on the circuit board. magnetic locks are wired to the Normally Closed (N.C.) contacts. Use 18 AWG wire for runs up to 100 Ft. Use 16 AWG wire for runs up to 200 Ft. 17 2.3.2 Controller & Expansion Boards 1-8 Auxiliary Terminals + for its programmed strike time. 16 Volt, 20 VA UL Listed Transformer. Controller main terminals 13-14 = SYSTEM RELAY 2. NOTES: Controller main terminals 15-16-17 = SYSTEM RELAY 1. 1833, 1835, 1837, 1838 CONTROLLERMain Terminal 30 Series Controller to 2351-010 Expansion Boards 1-8 Detail WiringRelay 0 is not available on the 1838 controller. For 1837, use 16 Volt, 40 VA UL Listed Transformer. No connection at controller. Battery Backup - separate batteries required for phone system and weigand terminals. See Dwg No. M1835-065-5 for detail. 18 2.3.3 Controller & Expansion Boards 1-16 Auxiliary Terminals Page 18 1838-065-L-3-10 + Relay 0 is not available on the 1838 controller. Controller main terminals 13-14 = SYSTEM RELAY 2. NOTES: Controller main terminals 15-16-17 = SYSTEM RELAY 1. Main Terminal 1833, 1835, 1837, 1838 CONTROLLER 30 Series Controller to 2351-010 Expansion Boards 1-16 Detail WiringCentral Office phone line - touch tone, loop start. 16 Volt, 20 VA UL Listed Transformer. For 1837, use 16 Volt, 40 VA UL Listed Transformer. No connection at controller. See Dwg No. M1835-065-5 for detail. + 19 2.3.4 Controller and 1838-120 & 121 Remote Call StationsAuxiliary Terminals 1838 CONTROLLER 20 2.3.5 Controller and 1504-120 & 121 Remote Call StationsAuxiliary Terminals 1838 CONTROLLER 21 2.3.6 RS-232 Cable Connection 23 SECTION 3 PROGRAMMING 26 STOP!! 39 SECTION 4 OPERATING INSTRUCTIONS 41 SECTION 5 MAINTENANCE
Also you can find more DKS Enterprises manuals or manuals for other Computer Equipment.