3.2.4 Open Tone On or Off
The following programming sequence turns the open tone (when the relays activate) either On or Off.
This feature is available on Rev J boards or higher.
Factory setting = 1 (tone on)
1. Press * 1 5 and then enter the four digit master code _ _ _ _ (beep).
2. Enter 1 for yes (tone will sound) or 0 for no (tone will not sound) then press * (beep).
3. Press 0 # together to end this programming sequence (beeeeeep).
3.2.5 Elevator Control Function
This new elevator feature authorizes floor access to the Floor Level identified in the Resident Screen
in the software program AND to the floor(s) level identified in the Security Level screen. If this feature
is turned off, access will be granted only the floor identified in the user’s security level. This feature is
available on Rev J boards or higher.
1. Press * 7 5 and then enter the four digit master code _ _ _ _ (beep).
2. Enter 1 for yes (access is authorized to both the floor identified in the resident screen and
to the floor(s) identified in the user’s security level) or 0 for no (access is authorized only
to the floor(s) identified in the security level screen) then press * (beep).
3. Press 0 # together to end this programming sequence (beeeeeep).
3.2.6 RS-232 Speed Setting
The following programming sequence sets an optional faster RS-232 speed. This feature is available
on Rev L boards or higher and the Remote Account Manager Software, Version 6.2, must be used.
Factory setting = 0 (9600 baud rate)
1. Press * 8 5 and then enter the four digit master code _ _ _ _ (beep).
2. Enter 0 for 9600 baud rate or 1 for 19200 baud rate then press * (beep).
3. Press 0 # together to end this programming sequence (beeeeeep).
STOP!!
If the access control system is to be programmed from a PC, no other programming is required at the
system itself. Refer to the Remote Account Manager for Windows Software help screens for
additional programming information. Continue with the remaining sections in this chapter if the
access control system will be programmed by any other method. If the factory setting matches your
need, there is no reason to reprogram that section.
Remember that relay hold open time zones, security levels, and elevator control functions can only be
programmed from the Remote Account Manager Software. If any of these features are being used,
do not proceed with any other programming steps in this manual.
Page 26 1838-065-L-3-10