Field Controls Oil Venting Systems manuals
Kitchen Appliance > Range
When we buy new device such as Field Controls Oil Venting Systems we often through away most of the documentation but the warranty.
Very often issues with Field Controls Oil Venting Systems begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Range Field Controls Oil Venting Systems is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Range on our side using links below.
Field Controls Oil Venting Systems Manual
14 pages 975.03 Kb
VentingThe PVO Power Venter The SWG Aluminized Power Venter 2 Field Controls Product EvolutionNote: The SWG Stainless Power Venter The ComboVentEnergy Efficiency and Tighter Homes Homes without Chimneys Deteriorating Chimneys 3 The Evolution of VentingConventional Powe r Power Venting Direct Venting 4 The Evolution of VentingDirect Power Venting with Combustion Air 5 ComboVent Up to14" Specifications and Dimensions Model Volts Hz Amps Watts RPM A S t a i n l e s s S t e e lEasier to Service Telescoping stainless steel body Acc ommod ates wall s up to 14 " thic k D E CBNEW Protection A B C D E F A total system for combustion air and venting.77137FCHVentGuideOil_New:7137FCHVentGuideOil 5/8/08 10:44 AM Page 7 B A C D F E 6 SWG Stainless Power VenterBenefits of the SWG Power Venter include:Specifications and DimensionsReplacement Motor Kit and Stainless SteelModel shown. Model A B C D E F 7 Sizing The Power VenterSWG and ComboVent (CV) MODEL) Sizing The Venter(Use Maximum GPH Input Table 1- SWG-14 SWG-12 SWG-10 SWG-8 SWG-6, 6s SWG-5, 5s, CV-5 SWG-4HD, 4HDs, CV-4 PIPESIZEMaximumEquivalent Feet of Vent Pipe VENT SWG-3 8 Locating The Power VenterProcedure Calculating Equivalent Feet of a Vent System Usinga Reducer/Increaser Small Pipe Size Large Pipe Size Terminal Locations of a Vent System Table 3 9 Clearance to CombustiblesABB Single Pipe System Double Pipe System Pipe SizeDiag ram ANominal Cross-SectionalArea Sq.Inches 3" 7 4" 13 5" 20 6" 28 7" 38 8" 50 9" 64 10" 79 12" 113 14" 154 10 Control KitsModel Applications WMO-1 ControlKit Installation: Control Kits Model PartNo. Contact MaterialLoad-Rating (Amps) Load-Rating (Volts) NormallyClosed Switch Switch Type Application Thermal Safety Switch 11 System SetupProcedure for adjusting the pressure switch SYSTEM SETUP: TESTING: ANNUAL MAINTENANCE: 12 System Setup and Maintenance13 FieldDirectVenting SystemBenefits of FieldDirect Venting System How FieldDirect Venting Systems Work Fresh Air In Combustion Gases Out Installation Advantages of FieldDirect Venting System
Also you can find more Field Controls manuals or manuals for other Kitchen Appliance.