SMC Networks D-R K Series manuals
Computer Equipment > Switch
When we buy new device such as SMC Networks D-R K Series we often through away most of the documentation but the warranty.
Very often issues with SMC Networks D-R K Series begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Switch SMC Networks D-R K Series is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Switch on our side using links below.
SMC Networks D-R K Series Manual
8 pages 578.87 Kb
OUT2 1 detect2 Internal CircuitSpecifications D-RNK D-RPK 3 DescriptionsApplicable actuator and operation range (angle) Air gripper Air cylinder 4 Dimensions5 "Caution", "Warning"Danger 6 Be sure to read before handlingDesign & Selection 1. Confirm the specifications 2. Take precautions when multiple cylinders are used close together 3. Keep the wiring as short as possible 4.Take precautions for the internal voltage drop of the switch 5.Pay attention to leakage current 6. Cautions for use in an interlock circuit 7. Ensure sufficient clearance for maintenance activities Mounting & Adjustment 1. Do not drop or bump 2. Do not carry a cylinder by the auto switc lead wires 3. Mount switches using the proper tightenin torque Wiring 1.Avoid repeatedly bending or stretching lea wires 3.Confirm proper insulation of wiring 4.Do not wire with power lines or high voltag lines 5. Do not allow short circuit of loads 6. Avoid incorrect wiring 7 Operating Environment1. Never use in an atmosphere with explosive gases 2. Do not use in an area where a magnetic field is generated 4. Do not use in an environment with oil or chemicals 5. Do not use in an environment with temperature cycles 6.Do not use in an area where surges are generated 7. Avoid accumulation of iron powder or close contact with magnetic substances 8.Take measures against freezing when operating at 5°C or less Maintenance Other 8 1.Connection and removal of connectorMounting of Amplifier Unit 1.Mounting with screws 2.Connection of sensor connector 2. Mounting and removal to DIN rail 3.Refer to each applicable actuator's catalogu for the mounting of sensor unitAustria Belgium Norway Bulgaria Poland Portugal Denmark Romania Estonia Russia Finland Slovakia France Slovenia Germany Spain Greece Sweden Hungary Ireland Turkey Italy
Also you can find more SMC Networks manuals or manuals for other Computer Equipment.