Trimmer Auto Switch

D-￿7K/D-R￿K

Sensor unit

Direct mounting type

Rail mounting type

Amplifier unit

Internal Circuit

Sensor unit

D-￿7K

Vsw (Brown) Switch

main circuit

 

GND (Blue)

Detective

SOUT 1

(Black)

 

 

sensor

SOUT 2

(White)

 

Specifications

Sensor unit

Model

D-F7K

 

D-Y7K

Mounting

Rail mounting

 

Direct mounting

 

 

 

 

Applicable amplifier unit

D-RNK, D-RPK

 

 

 

 

Status indication

Operating position: red light is ON. Suitable operating position: green light is O

 

 

 

 

Electrical entry

Grommet

 

 

 

 

 

Lead wire

Oil proof vinyl heavy insulation cable ø3.5

0.14 mm2 4 cores 3

With one e-con connector Note)

 

Impact resistance

980 m/s2

 

Insulation resistance

50 M(500 VDC) between lead wire and case

 

 

 

Withstand voltage

1000 VAC for 1 min. between lead wire and case

 

 

 

 

Ambient temperature

–10 to 60 °C

 

 

 

 

 

Enclosure

IP67

 

 

 

 

Weight

58 g (with connector)

 

 

 

 

Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipme

Amplifier unit (with sensor unit)

Model

D-RNK

D-RPK

Applicable sensor unit

D-F7K, D-Y7K

 

 

 

Application

For relay and PLC

 

 

 

Power supply voltage

12 to 24 VDC

 

 

 

Current consumption

40 mA or less

 

 

 

Output specification

NPN open collector Two outputs

PNP open collector Two outpu

 

 

 

Load voltage

28 VDC or less

 

 

 

Amplifier unit

D-RNK

Sensor

 

 

 

 

Brown

 

 

 

 

4

 

 

 

 

 

 

 

 

White

 

 

circuit

 

3

 

 

 

 

 

 

 

 

Blue

2

 

Main

 

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC (+)

(Brown)

OUT 1

(Black)

OUT 2

(White)

DC (–) (Blue)

Load

Load

12 to 24

V DC

Load current

80 mA or less

Internal voltage drop

1.5 V or less

 

 

Leakage current

100 A or less

 

 

Response time

1 ms or less

 

 

 

READY: Red light emitting diode when the piston position detected

Status indication

(When the sensor is connected).

OUT 1: Green light emitting diode when ON

 

 

OUT 2: Orange light emitting diode when ON

 

 

Connection

e-con connector

to sensor

 

D-RPK

Sensor

 

 

 

 

 

 

 

Brown

 

 

 

 

 

 

 

 

 

4

 

 

circuit

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

Main

 

 

 

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC (+)

(Brown)

OUT 1 (Black) OUT 2 (White)

DC (–)

(Blue)

Load

12 to 24

V DC

Load

Electrical

 

 

 

entry

Power supply/

 

 

 

Grommet

 

 

output cable

 

 

 

 

 

 

 

Lead wire

 

Oil proof vinyl heavy insulation cable ø3.5 0.14 mm2 4 cores 3

 

 

 

Impact resistance

98 m/s2

 

 

 

Insulation resistance

50 M(500 VDC) between lead wire and case

 

 

 

Withstand voltage

1000 V AC for 1 min. (between lead wire and case)

 

 

 

Ambient temperature

–10 to 60 °C

 

 

 

Enclosure