Trimmer Auto Switch D-￿7K/D-R￿

Descriptions

Sensor unit

2

1

 

1

 

2

D-F7K

D-Y7K

Amplifier unit

1

2

3

4

5

6

7

D-R￿K

Sensor unit

 

Red light turns ON when sensor detects

1 Indicator light

the magnet field. Green light is ON durin

the suitable position to detect the magne

 

 

field (including most sensitive position).

ø3.2 mounting hole

2 M2.5 x 4L slotted Fixes the sensor to the actuator. set screw

Amplifier unit

1

Output (OUT1) indication: green

Lights up when OUT1 outputs.

2

OUT1 adjusting trimmer

Adjusts the output range of OUT1 whe

sensor unit detects the magnetic field.

 

 

3

Output (OUT2) indication: orange

Lights up when OUT2 outputs.

4

OUT2 adjusting trimmer

Adjusts the output range of OUT2 whe

sensor unit detects the magnetic field.

 

 

 

Confirmation of detection at

Lights up when sensor unit is detecting th

5

magnetic field. While its lighting, output

sensor unit (READY): red

 

ranges of OUT1 and OUT2 are adjustabl

 

 

 

 

Adjusts the sensor unit at the time of connectio

 

Offset adjusting trimmer

Once adjusts, no need to re-adjust as lon

6

as the sensor unit is not replaced.

(ADJ)

Adjustment must be undertaken while the

 

 

 

sensor unit is removed from the actuator.

 

 

Refer to the operation manual for details.

7

Confirmation of offset

Lights up when offset adjustment is

adjustment (OFFSET): red

completed.

 

 

 

 

Refer to the operation manual for how to adjust/set.

Applicable actuator and operation range (angle)

The operating ranges are provided as guidelines including the hysteresis and are

guaranteed value. Consult SMC for alternative actuators than those shown below

Sensor unit D-Y7K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air gripper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm or ° )

Model

 

 

 

 

 

 

 

 

 

Bore size (mm)

 

 

 

 

 

 

 

 

 

10

 

12

 

16

20

25

 

32

40

 

50

63

80

100

 

 

 

 

 

 

 

 

Parallel gripper

MHZ2

4

 

5

7

7

 

8

8.5

 

 

 

 

Wide opening

MHL2

6.8

 

8

8.5

10.5

 

11

12.5

 

 

 

 

Parallel gripper

MHS2 (2 finger)

 

 

 

6.5

7

 

7.5

8.5

 

 

 

Parallel gripper

MHS3 (3 finger)

 

 

 

6.5

7

 

7.5

8

 

 

 

Parallel gripper

MHS4 (4 finger)

 

 

 

6.5

7

 

7.5

8.5

 

 

 

Angular gripper

MHC2

30° to –10°

30° to –10°

30° to –10°

22.5° to –10°

 

 

 

 

180° opening/closing

MHW2

88° to –5°

54° to –6°

58° to –5°

41° to –5°

30° to –4°

 

 

 

Air cylinder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compact

MGP

3.5

 

5

4.5

4.5

 

5.5

5.5

 

5.5

5.5

5.5

6

 

guide cylinder

 

 

 

 

Air cylinder

CA2

 

 

 

4

 

4

 

6

6

6

 

Sensor unit D-F7K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air cylinder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

Model

 

 

 

 

 

 

 

 

 

Bore size (mm)