3Com 1000BASE-SX quick start Module Status, Port Status

Models: 1000BASE-SX

1 24
Download 24 pages 41.28 Kb
Page 14
Image 14
Module Status

142-PORT 1000BASE-SXAND 2-PORT 1000BASE-LX GIGABIT ETHERNET INTERFACE MODULES QUICK START GUIDE

Verifying Module The GEN Interface Modules each have one Module Status LED and two Operation Port Status LEDs. Watch the LEDs during system power-on to verify

proper module operation. During the power-on diagnostic test, both the Module Status and Port Status LEDs flash for approximately 1 second, and then reflect the active status of the module as described in Table 3.

.

Table 3 Module and Port Status LED Indicators

LED

State and Color

Description

Module Status

Green

Power is on (normal operation).

 

Off

No power.

Port Status

Green

Port is enabled and link is up.

 

Flashing Green

Port is receiving or transmitting

 

 

packets.

 

 

Port is cabled but the switch fabric

 

 

module is down or unavailable.

 

Off

Link is disabled or port is not cabled.

Page 14
Image 14
3Com 1000BASE-SX quick start Module Status, Port Status