Page 2
General specifications
Model
Characteristics |
|
| Description |
|
| |
Display |
|
| 3 ½ Digit LCD display |
|
| |
Display Count |
|
| 3200 count, maximum reading 3199 |
| ||
|
|
|
| 32 segment analog bar graph |
|
|
Over range Indication |
|
| “OL” displayed |
|
| |
Sampling Rate |
|
| 2 time/second |
|
| |
Operating Environment: |
| 0°C to 50°C (32°F to 122°F) 70%RH |
| |||
Relative Humidity |
|
|
|
|
| |
Temperature Coefficient |
| 0.05X x (accuracy) per °F (32°F to 65°F, 85°F to 122°F | ||||
Storage Environment: |
|
| ||||
Power source: |
|
| 9V Battery (NEDA 1604) |
|
| |
Battery Live: |
|
| 200 hours typical (alkaline) |
|
| |
Low Battery Indicator: |
|
| symbol indicates low battery voltage | |||
Auto Power Off mode |
|
| Approximately 25 minutes |
|
| |
A protection Fuse |
|
| 0.5A/250V fast acting fuse Type | |||
|
|
|
| 10A/600V fast acting fuse, Type | ||
Dimensions |
|
| 5.75” H X 2.75” W X 1.5” D {without holster} | |||
Weight: |
|
| Approximately 18.0 oz. including battery | |||
Safety |
|
| UL1244, and Design to comply with IEC | |||
RANGES and ACCURACY SPECIFICATION |
|
| ||||
|
|
|
|
|
|
|
Function Setting |
| Ranges |
| Accuracy | ||
AC Voltage |
| 3.200V/32.00V/320.0V/ 600V | 2.0% | ± 4 digits | ||
| 50Hz to 500Hz |
|
| |||
|
|
|
| |||
DC Voltage |
| 320.0mV/32.00V/320.0V/600V | 1.2% | ± 1digit | ||
| 3.200V |
| 0.8% | ± 1digit | ||
|
|
| ||||
AC Current |
| 320µA/3200 µA/32.00mA/320mA | 2.5% | ± 4 digits | ||
| 10A, |
| 3.5% | ± 4 digits | ||
|
| 50Hz to 500Hz |
|
| ||
DC Current |
| 320µA/3.20mA/32.00mA | 2.0% | ± 1 digit | ||
| 10A, |
| 3.0% | ± 1 digit | ||
|
|
| ||||
|
| 320.0Ω |
| 2.0% | ± 3 digits | |
Resistance |
| 3.200k/32.00k/320.0k | 1.5% | ± 3 digits | ||
| 3.200MΩ |
| 2.5% | ± 3 digits | ||
|
|
| ||||
|
| 32.00MΩ |
| 5.0% | ± 5 digits | |
Continuity |
| beep on < 100Ω | Not Specified | |||
Diode Check |
| 2V DC max | 10% ± 2 digit | |||
AC Converter: | Average responding, RMS Calibrated to Sine Wave | |||||
Overload Protection: | AC and DC Volts: 600V DC or AC rms . |
| ||||
|
| Resistance, Diode, Continuity: 500V DC or AC rms |
mA input: .5A/250V DC/AC rms
Amps input: 10A/600V DC/AC rms
Form number 61362 | rev 1 May 2002 |