Applicable Literature

F-Number

Description

 

Audience

Purpose

 

 

 

 

 

 

 

Sales Personnel

Describes the globe valve

 

MX40-6XXX-2XX, MX40-7XXX-2XX Series

Application Engineers

actuator/linkage assembly’s features,

F-26750

Installers

specifications, and possible applications.

Actuator/Linkage Assemblies General Instructions

 

Service Personnel

Provides step-by-step mounting

 

 

 

 

Start-up Technicians

instructions.

 

 

 

 

 

 

 

Sales Personnel

Provides actuator specifications and part

 

 

Application Engineers

 

MX40-7XXX, MX40-6XXX Series DuraDrive Actuator

number cross referencing of phased out

F-26646

Installers

Selection Guide

actuators with the new direct-coupled

 

Service Personnel

 

 

actuators.

 

 

Start-up Technicians

 

 

 

 

 

 

 

 

 

VX-2000, VX-7000 Series

Sales Personnel

Provides part number cross referencing of

 

Application Engineers

 

MX40-7XXX, MX40-6XXX Series

F-26752

Installers

phased out actuators with the new direct-

Ball/Linked Globe Valve Assemblies

 

Service Personnel

coupled actuators.

 

Actuator/Linkage Assemblies Selection Guide

 

Start-up Technicians

 

 

 

 

 

 

 

 

 

 

 

Application Engineers

Describes Schneider Electric approved

F-26080

EN-205 Water System Guidelines

Installers

Service Personnel

water treatment practices.

 

 

 

 

Start-up Technicians

 

 

 

 

 

 

F-13755

CA-28 Control Valve Sizing

Application Engineers

Provides charts, equations, and diagrams

 

 

to assist in the configuration of valve

F-11080

Valve Selection Chart Water

Installers

system applications. TOOL-150, valve

 

 

Service Personnel

F-11366

Valve Selection Chart Steam (two-way valves only)

sizing slide rule may be purchased

Start-up Technicians

separately.

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Inputs

Control Signal: 4 to 20 mAdc (with the addition of a 500 Ohm resistor - not included) or 2 to 10 Vdc. See Figure-1through Figure-8.

Power Input: See Table-1.All 24 Vac and 22-30 Vdc circuits are Class 2. All circuits 30 Vac and above are Class 1.

Impedance: 2 to 10 Vdc, 121kΩ. 4 to 20 mAdc, 500Ω. (user supplied).

Connections:

Class 1 Power, 24 inch (61 cm) long, 18 AWG color coded pigtail leads.

Class 2 Power & Control, 36 inch (91 cm) long, 22 AWG color coded appliance cable leads.

Ground, 36 inch (91 cm) long, 18 AWG green/yellow pigtail lead.

Outputs

Electrical:

Position Feedback Voltage, “AO” 2 to 10 Vdc (max. 0.5 ma) output signal for position feedback or to operate up to four additional slave actuators.

Stroke, Electronically limited to 92° ±1°.

Action, Direct acting, 0° position with 4 mAdc or 2 Vdc input. Torque See Table-1.

Duty Cycle 100%.

Timing See Table-1.

Mechanical:

Anti-Rotation Bracket,

Standard 9" long x 13/16" wide (229 x 21 mm), included with the actuator. Optional Order AM-752 (4" long x 1-11/16" wide) for mounting the actuator in narrow spaces.

Universal Mounting Clamps, Two clamps are required for all mounting configurations. Standard 3/8" to 1/2" (10 to 13 mm) round and square shaft mounting clamps are included with the actuator.

Optional Order AM-753 for 5/8" (16 mm) square and 3/4" to 1" (19 to 25 mm) round damper shafts, two per package.

2