Induction Method
Transmitter
Hinge
| ||
Near End | Suspected | Far End |
Ground | Cable Path | Ground |
1.Place the transmitter on the ground over the target cable with the lid hinge in line with the cable path.
Dyna-Coupler Method (Optional Accessories Required)
Note: The coupler jaws
Pedestal must fully close for tone
To transmission.
Transmitter
Transmitter | Suspected | |
Cable Path | ||
| ||
|
1.Plug the
2.Clamp the
Transmitter Operation:
T | K |
| ||
L |
nsm n n
1.Hold down for Battery Test (solid tone=good; beeping tone=low; no tone=replace batteries).
2.Press to turn the unit on and select Continuity Test (solid tone=good ground; beeping tone= usable ground; no tone=poor ground or no far end ground). Both LEDs light continuously during the continuity test.
3.Press to apply Tracing Tone and select the desired frequency: 577 Hz for direct connect with far end ground; or 33 KHz for direct connect with no far end ground, or for use with coupler, or induction. LED indicates frequency selection. (This key can also turn the unit on.)
4.Press to change output level. Choose Normal output (flashing LED) for locating short to moderate distances using direct connect method. Use High output (solid LED) for coupler, induction, or direct connect for long distance.
5.When locating is complete, press to turn the unit off.
2