Initializing the System

Performance Series

!Important

1.Initialization will erase all memorized parameters and restore factory default values.

2.If Pump Mode (factory default) is desired, initialization is not required.

3.If software is upgraded, the system must be re-initialized.

Initialization instructions for Pump Mode (factory default)

Init PUMP Mode

‘TALK’ = Yes

1:PUMP MODE

Initialization Instructions for Island Mode

Init ISLAND Mode ‘TALK’ = Yes

Pump mode assigns each Call Station to a single number (1 through 24). Pump mode is used when there are 2 speakers per M.P.D., and each speaker serves one side of the dispenser.

Procedure 1: Press and hold the ALL CALL key while applying power to the Selector.

OR

Procedure 2: Reset or remove power from the Station Selector using one of the following methods:

a.Unplug the RS485 cable.

b.Press and hold the STD BY key while entering the numeric code 911.

Island mode assigns each Call Station to two consecutive numbers (1&2,, 3&4, …….). Island mode is used where a single speaker serves both sides of a

dispenser.

Procedure 1: Press and hold the HOLD key while applying power to any Selector.

OR

Procedure 2: Reset or remove power from any Station in one of the following ways.

a.Unplug the RS485 cable.

b.Press and hold the STD BY key while entering the numeric code 911.

Resetting the Station

To reset only the station selector:

Selector

1.

Press and hold the STD BY key.

(Reset)

2.

Enter the numeric code: 911.

Resetting the System

To reset only the entire system:

(Reset)

1.

Press and hold the STD BY key.

 

2.

Enter the numeric code: 8642.

DEFINITIONS:

 

1)

Power On Reset:

Turning off power, and then turning it back on. Commonly referred to as a “Cold Boot”.

2) Reset:

Restarting the micro controller firmware. Commonly referred to as the “Warm Boot.”

2)

Re-Initialize:

Over writes the EEPROM memory with factory default values. This process also selects “Pump” or “Island”

 

 

mode of operation

3)

Programming Mode:

change the EEPROM memory from factory default values to user preferences

10

Page 14
Image 14
3M 2475, 2470 Initialization instructions for Pump Mode factory default, Initialization Instructions for Island Mode

2475, 2470 specifications

3M has long been recognized as a leader in innovative solutions across various industries, and the 3M 2470 and 2475 are prime examples of the company's commitment to quality and technological advancement. These products are specialized filters that provide exceptional filtration performance, particularly in environments where air quality is a concern.

The 3M 2470 filter is designed for use in respiratory protection systems, specifically in conjunction with a half or full-face respirator. Its primary function is to filter out particulates and certain aerosols, making it an essential tool for professionals working in industries such as construction, healthcare, and manufacturing. The filter boasts a lightweight yet durable design, ensuring comfort for long periods of wear. One of the standout features of the 3M 2470 is its advanced electrostatic filtering technology, which enhances its efficiency in trapping airborne particles while reducing breathing resistance. This technology not only improves the filter's performance but also contributes to increased user comfort.

The 3M 2475 filter, on the other hand, is a versatile option that combines particulate and gas vapor filtration. It is particularly beneficial for environments where both dust and chemical exposure are present. Like the 2470, the 2475 utilizes advanced filtration technology, incorporating cartridges that can effectively capture harmful gases, vapors, and particulate matter. This dual protection feature makes the 2475 filter an excellent choice for industries such as paint spraying, chemical processing, and in laboratories.

Both the 2470 and 2475 filters are designed with ease of use in mind. They can be effortlessly attached to compatible respirators and feature a low-profile design that minimizes obstruction during use. The filters' compatibility with numerous 3M respirator models ensures that professionals can easily integrate them into their existing safety gear.

In terms of characteristics, both models excel in delivering high levels of filtration efficiency, with the 2475 offering enhanced protection against specific gases. The filters are also designed to maintain a compact and lightweight profile, making them suitable for use in a variety of demanding environments. Furthermore, the materials used in these filters are both robust and resistant to wear, ensuring longevity and reliability in challenging conditions.

Overall, the 3M 2470 and 2475 filters exemplify the company's dedication to creating innovative and effective respiratory protection solutions. With their advanced technologies, user-friendly designs, and exceptional performance characteristics, these filters represent a crucial investment for professionals seeking to enhance their safety and health in the workplace.