User Display Settings

General Operation

When the system is operating, one of two displays will be shown. Pressing NEXT will alternate between the displays. One of the displays is always the current time of day. The sec- ond display is one of the following: days remaining or gallons remaining. Days remaining is the number of days left before the system goes through a regeneration cycle. Capacity re- maining is the number of gallons that will be treated before the system goes through a regeneration cycle. The user can scroll between the displays as desired.

OR

REGEN TODAY will be displayed if a regeneration is expected “Tonight.”

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display.

When water is being treated (i.e. water is flowing through the system) the word “SOFTENING” flashes on the display if a water meter is in- stalled.

Regeneration Mode

Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when members of a household are asleep. If there is a demand for water when the system is regenerating, untreated water will be used.

When the system begins to regenerate, the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed. The system runs through the steps automatically and will reset itself to help provide treated water when the regeneration has been completed.

Manual Regeneration

Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually referred to as manual regen- eration. There may be a period of heavy water usage because of guests or a heavy laundry day.

REGEN TODAY will Flash if a regeneration is expected “Tonight.”

To initiate a manual regeneration at the present delayed regeneration time, press and release “REGEN”. The words “REGEN TODAY” will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time.

NOTE: If you pressed the “REGEN” button in error, pressing the button again will cancel the request.

To initiate a manual regeneration immediately, press and hold the “REGEN” button for 3 seconds. The system will begin to regenerate immedi- ately. The request cannot be cancelled.

NOTE: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.

Set Time of Day

The user can also set the time of day. Time should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power out- ages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset.

Step 1 - Press SET CLOCK.

Step 2 - Current Time (hour): Set the hour of the day using or button. AM/PM toggles after 12. Press NEXT to go to Step 3.

Step 3 - Current Time (minutes): Set the minutes of the day using or buttons.

Press NEXT to exit Set Clock. Press “REGEN” to return to previous step.

3-4

Page 12
Image 12
3M CSFM1254 operating instructions User Display Settings, General Operation

CSFM1254 specifications

The 3M CSFM1254 is a sophisticated communication headset designed specifically for industrial and construction environments where effective communication is critical. This headset combines advanced technology, comfort, and durability, making it an ideal choice for professionals who work in demanding conditions.

One of the standout features of the 3M CSFM1254 is its high-performance noise-canceling capabilities. The headset is equipped with advanced passive noise reduction technology that effectively reduces background noise, allowing users to communicate clearly even in noisy environments. This is particularly important in construction sites or manufacturing facilities where heavy machinery and equipment can create significant auditory distractions.

The 3M CSFM1254 utilizes a robust dual-ear design that provides enhanced sound isolation, further improving the user experience. The ear cups are designed for comfort, featuring cushioned padding that ensures a secure fit during extended use. This comfort, combined with an adjustable headband, allows for personalized fitting, making it suitable for all-day wear in various work situations.

Another highlight of the headset is its reliable communication capabilities. The built-in microphone is noise-canceling as well, which means that it fosters clear and effective communication by minimizing interference from surrounding noise. Users can expect consistent audio quality, enabling them to stay connected with colleagues and supervisors without the frustration of interrupted or inaudible conversations.

Durability is a defining characteristic of the 3M CSFM1254. It is constructed with high-quality materials that can withstand the rigors of challenging work environments. The headset has been tested for various impacts and environmental conditions, making it a reliable choice for those who need equipment that can keep up with their demanding work routines.

In terms of connectivity, the 3M CSFM1254 offers versatile options, allowing it to be easily integrated with various communication systems, including two-way radios and smartphones. This flexibility enhances workplace communication efficiency, enabling teams to coordinate tasks and safety measures effectively.

Overall, the 3M CSFM1254 headset stands out as a top choice for professionals who require reliable, clear communication and durability in their headsets. With its combination of noise-canceling technology, comfort, and robust build, it addresses the needs of those working in high-noise environments, ensuring they remain connected and safe while performing their tasks.