3M MP8740 manual Troubleshooting, Sympton/Solution Table, Message/Solution Table

Models: MP8740

1 34
Download 34 pages 3.78 Kb
Page 20
Image 20
Section 7: Troubleshooting

Section 7: Troubleshooting

7.1 Sympton/Solution Table

 

 

 

ENGLISH

Symptom

Cause

Solution

 

 

 

 

 

Power cannot be turned

• The Main power is not turned on.

• Turn the MAIN POWER switch on.

 

on.

• The power cord is disconnected.

• Insert the power cord into an AC socket.

 

 

 

 

 

 

 

No picture and sound

• The setting of the input source is not

• Set the correct input using the input select button

 

 

correct.

of the projector or the remote control.

 

 

•RGB/Video/Audio wiring to projector is

• Connect the cable to correct input/output source.

 

 

not correct.

 

 

 

 

 

 

Sound is heard with

• RGB/Video wiring to projector is not correct.

• Connect the cable to correct input/output source.

 

• Press the MENU button and increase

 

no picture

 

 

 

• The brightness is set fully to dark.

BRIGHTNESS.

 

 

 

 

 

Picture is displayed

• Audio wiring to projector is not correct.

• Connect the cable to correct input/output source.

 

• The volume is set to minimum.

 

• Press the VOL button and increase VOLUME.

 

with no sound

 

 

• The unit is muted.

• Press the MUTE button.

 

 

 

 

 

Color is weak and tint is

• The color and tint have been adjusted

• Adjust the color and tint correctly.

 

incorrect

incorrectly.

 

 

 

 

 

 

 

Picture is dark

• The brightness and contrast has been

• Adjust the brightness and contrast correctly.

 

 

adjusted incorrectly.

 

 

 

 

 

• The lamp needs to be replaced.

• Replace the lamp with a new one.

 

 

 

 

 

 

 

 

Picture is not clear

• Projector is out of focus.

• Adjust the focus.

 

 

 

 

 

LAMP indicator lights

• Lamp will not ignite.

• Turn off power and let cool for 20 minutes, then restart.

 

red.

• If problem persists call your dealer.

 

 

 

 

 

 

 

LAMP indicator blinks

• Air filter door on bottom of case is open.

• Ensure air filter door is closed.

 

red.

 

 

 

TEMP indicator lights

• Temperature inside projector is too hot.

• Do not block the ventilation holes.

 

red.

 

• Clean air filter

 

 

 

 

 

TEMP indicator blinks

• Cooling fan may be obstructed by metal

• Align metal screen.

 

red.

screen under foam air filter.

• If fan blade is still obstructed, call service.

 

 

 

 

 

7.2 Message/Solution Table

 

Error Message Displays

Cause

Solution

 

 

 

 

 

 

 

NO INPUT IS DETECTED

The projector is not detecting a signal.

Check cable connections to input device. Input device not

 

 

 

 

connected to this input mode, switch to next mode.

 

 

 

 

 

 

 

SYNC IS OUT OF RANGE

The horizontal frequency of input signal

Switch projector to correct resolution.

 

 

 

exceeds projector capability.

See Appendix A.5

 

 

 

 

 

 

 

CHANGE THE LAMP

Lamp operation time is greater than 1,900

Change the projector lamp and reset the lamp operation

 

 

 

hours.

hours to zero.

 

 

 

 

 

 

 

RESET THE LAMP TIMER

Lamp operating time is greater than 2000

Change the projector lamp and reset the lamp operation

 

 

 

hours. Safety feature shuts projector down

hours to zero.

 

 

 

after 10 minutes.

 

 

 

 

 

 

 

 

CHECK THE AIR FLOW

Air flow to cooling fan is blocked.

Clear air flow path to fan and clean air filter.

 

 

 

 

 

 

 

 

 

 

 

© 3M 1999