WHAT TO DO WHEN YOU THINK A MACHINE DEFECT HAS OCCURRED (continued)

Regarding the Indicator Lamps

Lighting and flashing of the power indicator, the lamp indicator, and the temp indicator have the meanings as described in the Table below. Please respond in accordance with the instructions within the Table.

power

lamp

temp

Description

indicator

indicator

indicator

 

 

 

 

 

The orange

Turned OFF

Turned OFF

The STANDBY mode is set

lamp is lighted

(Not lighted)

(Not lighted)

 

 

 

 

 

Flashing of the green lamp

Turned OFF

Turned OFF

The unit is warming up. Please wait.

 

 

 

 

The green lamp is lighted

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

 

 

 

 

Flashing of the orange lamp

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

 

 

 

 

 

 

 

The unit is cooling down. Please wait.

Blinking of the

-

-

A certain error has been detected. Wait until the power indicator lamp has finished

red lamp

flashing, and then perform the proper response measure using the item descriptions

 

 

 

 

 

below as reference.

 

 

 

 

 

 

 

The lamp does not light.

The red lamp

The red lamp

Turned

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

is lighted, or

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

is lighted

OFF

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

blinks

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

 

 

 

turn the power ON again; if the same display is displayed, then please change the lamp.

 

 

 

 

The red lamp

 

 

Either there is no lamp and/or lamp door, or either of these has not been properly fixed

Blinking of the

Turned

(attached). Turn the power OFF and wait approximately 45 minutes. After the main unit has

is lighted, or

sufficiently cooled down, please make confirmation of the attachment state of the lamp and

red lamp

OFF

blinks

lamp door. After performing any needed maintenance, turn the power ON again; if the same

 

 

 

 

 

display is displayed, then please contact a sales store or a service company.

 

 

 

 

The red lamp

Turned

Blinking of the

The cooling fan is not operating. Turn the power OFF and wait approximately 20 minutes. After the

is lighted, or

main unit has cooled down, please make confirmation that no foreign matter has become caught in

OFF

red lamp

the fan, etc. After performing any needed maintenance, turn the power ON again; if the same display

blinks

 

 

is displayed, then please contact a sales store or a service company.

 

 

 

 

 

 

 

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

The red lamp is

Turned

The red lamp is

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

lighted, or

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

OFF

lighted

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

blinks

 

 

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green lamp

Alternative blinking

There is a possibility that the interior portion has become overcooled. Please use the unit within

the usage temperature parameters (0°C to 35°C). After performing any needed maintenance,

is lighted

with the red lamp

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green

Simultaneous blinking

This is a notification that it is time to clean the filter.

After cleaning the filter, operate the FILTER TIME portion of the OPTION Menu, and perform

lamp is lighted

with the red lamp

reset of the FILTER TIME.

 

 

 

 

 

 

 

NOTE

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the indicator lamps may also be turned OFF. Press the “” (power OFF) side of the main power switch, and wait for approximately 20 minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.

35

Page 36
Image 36
3M X40C, S40C manual Regarding the Indicator Lamps, Power Lamp Temp Description

X40C, S40C specifications

3M S40C and X40C are two highly advanced adhesive products that have transformed the way industries approach bonding and sealing applications. Both are part of 3M’s extensive portfolio, known for their cutting-edge technologies and unparalleled performance.

The 3M S40C is particularly noted for its exceptional strength and versatility. This adhesive is designed for a variety of substrates, including metals, plastics, and composites. Its primary feature is its high shear strength, which allows it to withstand significant load and stress, making it ideal for demanding applications in automotive, aerospace, and construction sectors. The S40C formulation includes advanced polymer technology that enhances adhesion while providing resistance to environmental factors such as moisture, temperature fluctuations, and chemical exposure.

In terms of application, the S40C offers excellent workability. Its user-friendly nature allows for easy dispensing and spreading, reducing application time and increasing efficiency. The curing process is also an important aspect; the adhesive typically cures at room temperature, but can be accelerated with heat, allowing for faster project turnaround times. Additionally, the S40C is known for its rapid bonding capabilities, which can significantly improve production flow in industrial settings.

On the other hand, the 3M X40C brings a unique combination of performance and flexibility. This adhesive is specifically engineered for applications requiring a balance between flexibility and strength. It is especially suitable for bonding materials that may experience expansion and contraction, such as rubber and certain plastics. The X40C features a different polymer matrix designed to absorb shock and vibration, which is crucial for applications in industries like electronics and transportation.

One of the standout characteristics of the X40C is its resistance to harsh environmental conditions. Whether exposed to UV rays, extreme temperatures, or chemicals, the X40C maintains its adhesion properties, ensuring long-lasting performance even in challenging environments. It also offers excellent clarity, making it a popular choice for applications where aesthetics are a consideration.

Both the S40C and X40C exemplify 3M’s commitment to innovation and quality. They are manufactured with stringent quality control measures in place, ensuring consistent performance and reliability. As industries continue to evolve, these adhesives represent the forefront of bonding technology, providing solutions that are not only effective but also efficient and sustainable. Whether through unparalleled strength or remarkable flexibility, 3M S40C and X40C are set to lead the way in adhesive applications across multiple sectors.