Management Blade | Control and Connection Panel | |
|
| |
4 | LAN active indicator (amber LED) | |
| Lights amber: | The LAN is active. |
| Blinks amber: | Boot up power ready indicator. |
|
|
|
5 | I2C connector |
|
| Proprietary I2C (IPMI) connector for Fujitsu Siemens Computers service | |
| applications. |
|
|
| |
6 | Failure indicator (amber LED) | |
| Dark: | This management blade is OK (see table below). |
| Lights amber: | If only one management blade is present: this blade has |
|
| failed (see table below). |
| Blinks amber | Management blade is running in power up mode (gener- |
| (2 sec.): | ating heart beat for master/slave selection). |
|
| |
7 | Master indicator (green LED) | |
| Unlit: | This management blade is a slave (standby), backup of |
|
| the master management blade (see table below). |
| Lights green: | This management blade is the master, responsible for |
|
| the entire system management (see table below). |
| Blinks green: | This management blade is in special mode |
|
|
|
The following table shows the conditions of the management blades indicated by the interaction of master indicator and failure indicator LEDs.
Management blade condition | Master indicator | Failure indicator |
| (green LED) | (amber LED) |
|
|
|
One management blade is | ON | OFF |
installed and alive |
|
|
|
|
|
Two management blades are | ON (Master) | OFF |
installed | OFF (Slave) |
|
|
|
|
One management blade is | ON | ON |
installed and hangs up |
|
|
|
|
|
Two management blades are | ON | ON |
installed and both hang up |
|
|
|
|
|
PRIMERGY BX600 S2 Basic Unit | 127 |