Management Blade

Control and Connection Panel

 

 

4

LAN active indicator (amber LED)

 

Lights amber:

The LAN is active.

 

Blinks amber:

Boot up power ready indicator.

 

 

 

5

I2C connector

 

 

Proprietary I2C (IPMI) connector for Fujitsu Siemens Computers service

 

applications.

 

 

 

6

Failure indicator (amber LED)

 

Dark:

This management blade is OK (see table below).

 

Lights amber:

If only one management blade is present: this blade has

 

 

failed (see table below).

 

Blinks amber

Management blade is running in power up mode (gener-

 

(2 sec.):

ating heart beat for master/slave selection).

 

 

7

Master indicator (green LED)

 

Unlit:

This management blade is a slave (standby), backup of

 

 

the master management blade (see table below).

 

Lights green:

This management blade is the master, responsible for

 

 

the entire system management (see table below).

 

Blinks green:

This management blade is in special mode

 

 

 

The following table shows the conditions of the management blades indicated by the interaction of master indicator and failure indicator LEDs.

Management blade condition

Master indicator

Failure indicator

 

(green LED)

(amber LED)

 

 

 

One management blade is

ON

OFF

installed and alive

 

 

 

 

 

Two management blades are

ON (Master)

OFF

installed

OFF (Slave)

 

 

 

 

One management blade is

ON

ON

installed and hangs up

 

 

 

 

 

Two management blades are

ON

ON

installed and both hang up

 

 

 

 

 

PRIMERGY BX600 S2 Basic Unit

127

Page 127
Image 127
Fujitsu BX600 S2 LAN active indicator amber LED, I2C connector, Failure indicator amber LED, Master indicator green LED