Installing the System in the Rack

Installing the Hardware

4.3.1Mounting the Assembly Kit

Mounting the server in the PRIMECENTER/DataCenter Rack requires the following parts:

two support brackets

two carrier rails (assembled)

12 plug washers (figure 7 on page 39) and screws

IFor general information see the technical manual for the relevant rack (see also “Related Publications” on page 165).

To mount the PRIMERGY BX600 S2 basic unit in the rack, you must first mount two support brackets on the rear left support upright of the rack. The first one must be mounted level with the lower edge of the device, while the second must be mounted level with the upper edge of the first. The brackets are used for the rear fixing of the left carrier rail.

ÊSee the installation instructions in the technical manual for the relevant rack model.

ÊMark the position of the lower edge of the basic unit on the support uprights.

1

Figure 6: Mounting the support brackets

ÊPlace the first support bracket at the appropriate height (level with the lower edge of the device) on the left rear support upright by inserting the positioning nubs (1 in figure 6) in the corresponding holes of the support upright.

ÊPlace the plug washers in the holes of the support uprights and secure the bracket with two screws.

38

PRIMERGY BX600 S2 Basic Unit

Page 38
Image 38
Fujitsu BX600 S2 manual Mounting the Assembly Kit, Mounting the support brackets