Important Notes

Components With Electrostatic-Sensitive Devices

3.2Components With Electrostatic-Sensitive Devices

Electrostatic-sensitive components are identified by the following sticker:

Figure 2: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

Always discharge static build-up (e.g. by touching a grounded object) before working.

The equipment and tools you use must be free of static charge.

Always hold components with ESDs by their edges.

Do not touch any exposed pins or conductors on a component.

Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

Place all components on a static-proof base.

IYou will find a detailed description of how to handle ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

3.3CE Certificate

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC “Electromagnetic compatibility” and 73/23/EEC “Low voltage directive”. The device therefore qualifies for the CE certificate (CE=Communauté Européenne).

PRIMERGY BX600 S2 Basic Unit