Fujitsu BX600 S2 manual Floppy Disk Cannot Be Read/Written, Time and Date Are Not Correct

Models: BX600 S2

1 173
Download 173 pages 6.42 Kb
Page 159
Image 159
16.8Floppy Disk Cannot Be Read/Written

Troubleshooting and Tips

Floppy Disk Cannot Be Read/Written

16.8Floppy Disk Cannot Be Read/Written

ÊCheck whether the write protection of the floppy disk is activated.

ÊCheck the entry for the floppy disk drive in the BIOS Setup for the corre- sponding server blade.

ÊCheck the BIOS Setup for the corresponding server blade to see whether the floppy disk drive controller and write permission are enabled.

16.9Time and Date Are Not Correct

ÊSet the time and/or date in the operating system or in the BIOS Setup for the corresponding server blade.

IIf the time and date are repeatedly wrong when you switch on your server blade, you must change the lithium battery (see the manual for the relevant server blade type).

16.10 Server Blade Does Not Boot

The server blade does not boot after a defective hard disk drive has been replaced

Incorrect SCSI configuration (onboard SCSI HostRAID controller)

ÊIn the SCSI configuration menu, check the settings for the hard disk drives (SCSI Device Configuration) and the additional settings (Advanced Config- uration Options).

16.11 Defective Drive

Drives are identified as dead on system start

The configuration of the RAID controller is wrong.

ÊCheck and correct the settings for the drives using the utility for the RAID controller.

For more details, see the manual for the RAID controller (on the ServerBooks CD under the heading “Controllers”).

PRIMERGY BX600 S2 Basic Unit