Troubleshooting
Install
ID/error LED green LED
Power indicator bicolor LED
Connecting External Devices
Management Blade Configuration
Before Setting Up
RJ45 connectors
Mounting the Assembly Kit
Exchanging the Battery
Page 70
Image 70
Page 69
Page 71
Page 70
Image 70
Page 69
Page 71
Contents
Primergy BX600 S2 Basic Unit
Copyright and Trademarks
Comments… Suggestions… Corrections…
Certified documentation according to DIN EN ISO
Contents
Contents
Contents
Power Supply Concept
Introduction
Concept and Target Group of this Manual
Overview of the Documentation
Overview of the Documentation
Additional server documentation
Introduction
Further Sources of Information
Server capacity
Features
Features
Communication interfaces
Ethernet LAN Pass-Thru-Blade
Management blade
Ventilation
Power Supply
KVM-Blade
High Level of Availability and Failure Protection
Server Management
Service and Support
ServerStart
Notational Conventions
Notational Conventions
Technical Data
Weight
Technical Data
Mechanical Values
Environmental Conditions
Noise Level
Page
Overview Basic Unit Installation Steps
Overview Basic Unit Installation Steps
Important Notes
Before Setting Up
Important Notes
Batteries
Other Important Notes
Components With Electrostatic-Sensitive Devices
CE Certificate
FCC Class a Compliance Statement
FCC Class a Compliance Statement
Transporting the Basic Unit
Important Notes
Environmental Protection
Environmentally Friendly Product Design and Development
Environmental Protection
Returning Batteries
Local Contacts
Page
Installation Steps
Installing the Hardware
Installing the Hardware
Unpacking the Basic Unit
Unpacking the Basic Unit
Requirements of the Rack
Installing the System in the Rack
PRIMECENTER/DataCenter Rack
Installing the System in the Rack
3rd-Party Rack
Mechanical conditions Primergy BX600 S2 Basic Unit
Mounting the Assembly Kit
Mounting the support brackets
Repeat the procedure with the second support bracket
Mounting/Removing the Basic Unit
Mounting the basic unit
Connecting External Devices
Connecting External Devices
Connectors on the back of the basic unit
Cable Routing
PCI Cards with Cable at the Front
Connecting External Devices Installing the Hardware
Connecting Cables
Instructions on Connecting and Disconnecting Cables
Disconnecting Cables
Connecting the System to the Mains
Connecting the System to the Mains
Connecting the System to the Mains
Page
Preparation for Use and Operation
Primergy BX600 S2 basic unit Primergy BX600 S2 Basic Unit
Power indicator bicolor LED
Operating and Indicator Elements of the Basic Unit
Operating and Indicator Elements
System power ON/OFF button
Preparation for Use and Operation
Front identify/Fault indicator amber LED
Front identify button
Rear
Rear identify/Fault indicator green LED1
Rear identify button1
Switching on the Basic Unit Basic Unit is Powered OFF
Switching the Basic Unit ON/OFF
Switching OFF the Basic Unit System is Powered on
Switching the Server Blades ON/OFF
Switching the Blade Server ON/OFF
After power failure
Specified switch-ON time/switch-OFF time
Initial Configuration via Serial Connection to Client
Management Blade Configuration
Pre-Configuration Requirements
Cabling the System
Management Blade Configuration
Log in as root. The initial password reads root
Enter 1 to call up the Management Agent Information menu
Management Agent Information menu
Agent NIC Duplex Mode menu
Updating System Components
Updating the Server Blade Firmware Bios and BMC
Proceed as follows
Updating the server blade Bios via the web interface
Updating the Management Blade Firmware
Updating the server blade BMC via the web interface
Updating the management blade firmware via the web interface
Updating the Switch Blade Firmware
Press Ctrl-Q Return Console Menu
Removing an operation code image file
Click Transfer from Server
Page
Preventing Unauthorized System Access
Bios Setup Security Functions
Preventing Unauthorized Bios Setup Calls
Preventing Unauthorized Boot Process
Page
Server Blades
Page
Installation Sequence
Server Blades
Installation Sequence Server Blades
Configuration Diagram for 2-way Server Blades
Configuration Diagram for 4-way Server Blades
Installation sequence for 4-way server blades
Adding a Server Blade to the Basic Unit
Removing the Dummy Module
Adding a Server Blade to the System
Adding a Server Blade to the System Server Blades
Inserting the Server Blade
Inserting the server blade
Removing the Server Blade
Final engaging of the locking mechanism
Ethernet LAN Switch Blades
Gbit Ethernet LAN Switch Blade SB9 6x1Gbit
LAN Switch Blade SB9 6x1Gbit
Ethernet Switch Blades
LAN Switch Blade SB9 6x1Gbit
Gbit Ethernet LAN Switch Blade SB9 6x1 Gbit + 2x10 Gbit
LAN Switch Blade SB9 6x1 Gbit + 2x10 Gbit
CX4 link/active indicator green LED
Cisco Catalyst Blade Switch
Cisco Catalyst Blade Switch
Ethernet Switch Blades
10 Gbit Switch Blade 10/2
Gbit Switch Blade 10/2
ID indicator green LED
Bedien- und Anschlussfeld
Port Assignment of the LAN Switch Blades
Port Assignment of the LAN Switch Blades
Configuration with Ten 2-way Server Blades
Configuration with Five 4-way Server-Blades
Installing a LAN Switch Blade
Vcaution
Installing a LAN Switch Blade
Removing the dummy module a = green touch point
Inserting the LAN Switch Blade
Disengaging the switch blade
Removing the Switch Blade
Page
Ethernet Pass-Thru Blade
Ethernet LAN Pass-Thru-Blade
Control and Connection Panel
RJ45 connectors
LAN activity indicator orange LED
Control and Connection Panel
Slots for installing pass-thru blades
Port Assignment of the Gigabit Ethernet Pass-Thru Blades
Port Assignment
Ethernet port assignment with ten 2-way server blades
Configuration with Five 4-way Server Blades
Replacing an Ethernet Pass-Thru Blade
Fibre Channel Switch Blade
Fibre Channel Switch Blade
IThe LED might also blink while testing
FC switch blade status display 2-color LED
107
Port Assignment
NET4 NET3
FC Switch Blade
Fabric port assignment with 2-way server blades
Fabric port assignment with five 4-way server blades
FC switch blade installation
Fabric port assignment with 4-way and 2-way server blades
Page
Fibre Channel Pass-Thru Blade
Fibre Channel pass-thru blade
114
Fibre Channel SFP module
Inserting a Fibre Channel SFP module
Fibre Channel SFP module
Removing an SFP Module
Port Assignment of the FC Pass-Thru Blades
Slot numbering for the Fibre Channel pass-thru blades
FC Port Assignment
Slot numbering for the SFP modules
119
120
FC Pass-Thru Blade
Exchanging an FC Pass-Thru Blade
Removing the FC pass-thru blade
Exchanging an FC Pass-Thru Blade
123
Page
Management Blade
Management blade slots
Serial port connector
LAN link indicator green LED Lights green The LAN is linked
Failure indicator amber LED
LAN active indicator amber LED
I2C connector
Master indicator green LED
Exchanging the Battery
Exchanging the Battery
129
Exchanging a Management Blade
Exchanging a Management Blade
Removing the Management Blade
131
Removing the management blade
KVM Blade
KVM Blade Standard Version
KVM Blade Standard Version
ID/error LED green LED
KVM connector
Control Panel of the KVM Blade Standard Version
KVM Blade
13.2 Adv. KVM Blade
Control Panel of the Adv. KVM Blade
LAN connection indicator orange LED
Rear ID/error LED green LED
LAN activity indicator green LED
Adv. KVM Blade
Digital KVM Blade
Digital KVM Blade
Power indicator
ID indicator
Control panel of the digital KVM blade
Power Supply Concept
PSU4 PSU3 PSU2 PSU1
Power Supply Units
Power Supply Units
Mains power supply display green LED
Power Supply Concept
Fault display amber LED
On/off display green LED
Replacing a Power Supply Unit
143
Removing the power supply unit
Adding a Power Supply Unit
Removing the PSU
PSU dummy module
147
Page
Ventilation Concept
FAN1 FAN2
Fan Unit
Fan Unit
Fan 1 LEDs Fan 2 LEDs Fan condition
Replacing the Fan Unit
Ventilation Concept
Removing the fan unit
Replacing a Fan in the Unit
Page
Wrongly connected power cables
Troubleshooting and Tips
System Power LED Remains Unlit
Power supply overloaded
Switch blade fails
Front or Rear Identify/Fault LED Blinks Amber
One of the power supply units fails
One of the fans in the rear fan modules has failed
System Switches Itself OFF
Screen Remains Dark
No Screen Display or Display Drifts
Flickering Stripes on the Monitor Screen
No Mouse Pointer Displayed On the Screen
Time and Date Are Not Correct
Server Blade Does Not Boot
Floppy Disk Cannot Be Read/Written
Defective Drive
Defective Drive
Added drive is identified as defective
Abbreviations
Abbreviations
NMI
USB
Related Publications
Safety Ergonomics Warranty DataCenter Rack
Primecenter Rack
166
167
Page
Index
Battery
Adding
Indicators
Index
LED
LAN
Unpacking
Information on this document
Hinweise zum vorliegenden Dokument
Top
Page
Image
Contents