IntroductionTechnical Data

1.4

Technical Data

 

Electrical Data (single power supply unit)

 

 

 

Rated voltage range

200 - 240 V

 

 

Rated frequency

50 Hz - 60 Hz

 

 

Max. rated current

230V / 11,6 A

 

 

Max. active power

230 V / 2650 W

 

 

Max. apparent power

2680 VA (230V)

 

 

Thermal dissipation

2050 kJ/h

 

 

Protection class

I

 

 

 

Electrical Data (basic unit without server blades)

Power consumption

 

360 W

 

 

 

Thermal dissipation

 

1300 kJ/h

 

 

 

Compliance Standards

 

 

 

 

Product safety and ergonomics

IEC 60950 / EN 60950 UL 1950 3rd Edition,

 

CSA 22.2 No. 950

 

 

Electromagnetic compatibility

FCC class A

Emitted interference

EN 55022 class A

Harmonic current

EN 61000-3-2

Noise immunity

EN 55024

 

 

CE label

Low-Voltage Directive 73/23/EEC

according to EU directives

Electromagnetic Compatibility 89/336/EEC

 

 

 

Certification

 

 

 

 

 

Product safety

 

 

 

 

Global

CB

 

 

 

PRIMERGY BX600 S2 Basic Unit

15

Page 15
Image 15
Fujitsu BX600 S2 manual Technical Data