Updating BX600 System Components Preparation for Use and Operation

Figure 23: Updating the server blade BMC via the web interface

5.4.2Updating the Management Blade Firmware

VCAUTION!

The procedure described below must be performed for each of the two management blades.

Proceed as follows:

ÊInstall your TFTP server software and start it. Copy the relevant firmware file (*.bin) to the root directory of the TFTP file system.

ÊCheck the LAN connection by pinging the relevant management blade.

ÊEnter the IP address of the TFTP server which provides the BMC image file for the management blade firmware. Enter the path and the file name of the image file for the management blade.

You have two options for doing this:

1.In the management console (Telnet) select the TFTP Upgrade submenu. Activate the option Management Blade/TFTP Update.

2.In the web interface of the management blade, select the entry System Property - Environment Maintenance - Firmware Update - Management Blade BMC Update.