Fujitsu BX600 S2 manual Updating the Switch Blade Firmware, Proceed as follows

Models: BX600 S2

1 173
Download 173 pages 6.42 Kb
Page 64
Image 64
5.4.3Updating the Switch Blade Firmware

Updating BX600 System Components Preparation for Use and Operation

5.4.3Updating the Switch Blade Firmware

IBefore you update the firmware, you must allocate IP addresses to the individual switch blades.

Proceed as follows:

ÊSwitch on the basic unit and start the management console (Telnet) of the management blade.

 

 

Console Menu

page_root

--------------------------------------------------------------------------------

 

 

(1)

Management Agent

 

 

(2)

Emergency Management Port

 

 

(3)

Console Redirection

 

 

(4)

TFTP upgrade

 

 

(5)

Logout

 

 

(6)

Reboot Management Blade

 

 

(7)

System Information Dump

 

 

Enter Selection: 3

 

 

ÊIn the management blade console, select the menu item Console Redirection.

 

Console Redirection Table

page_0.

--------------------------------------------------------------------------------

 

(1) Console Redirect Server Blade

 

(2)

Console Redirect Switch Blade

 

(3)

Set Return Hotkey , Ctrl+(a character) : 0

 

Enter selection or type (0) to quit: 2

 

ÊIn the Console Redirection Table menu, select the menu item Console Redirect Switch Blade.

64

PRIMERGY BX600 S2 Basic Unit

Page 64
Image 64
Fujitsu BX600 S2 Updating the Switch Blade Firmware, Updating BX600 System Components Preparation for Use and Operation