Basic Inspection

After power in connected to the AC servo drive, the charge LED will be lit which indicates that the AC servo drive is ready.

 

Item

 

Content

 

 

 

„ Periodically inspect the screws of the servo drive, motor shaft, terminal block and

 

 

 

the connection to mechanical system. Tighten screws as necessary as they may

 

 

 

loosen due to vibration and varying temperatures.

 

 

 

„ Ensure that oil, water, metallic particles or any foreign objects do not fall inside the

 

General Inspection

 

servo drive, motor, control panel or ventilation slots and holes. As these will cause

 

 

damage.

 

 

 

 

 

 

„ Ensure the correct installation and the control panel. It should be free from airborne

 

 

 

dust, harmful gases or liquids.

 

 

 

„ Ensure that all wiring instructions and recommendations are followed; otherwise

 

 

 

damage to the drive and or motor may result.

 

 

 

„ Inspect the servo drive and servo motor to insure they were not damaged.

 

 

 

„ To avoid an electric shock, be sure to connect the ground terminal of servo drive to

 

 

 

the ground terminal of control panel.

 

 

 

„ Before making any connection, wait 10 minutes for capacitors to discharge after

 

 

 

the power is disconnected, alternatively, use an appropriate discharge device to

 

 

 

discharge.

 

Inspection before

 

„ Ensure that all wiring terminals are correctly insulated.

 

 

„ Ensure that all wiring is correct or damage and or malfunction may result.

 

operation

 

„ Visually check to ensure that there are not any unused screws, metal strips, or any

 

(Control power is not

 

 

 

conductive or inflammable materials inside the drive.

 

applied)

 

 

 

„ Never put inflammable objects on servo drive or close to the external regenerative

 

 

 

 

 

 

resistor.

 

 

 

„ Make sure control switch is OFF.

 

 

 

„ If the electromagnetic brake is being used, ensure that it is correctly wired.

 

 

 

„ If required, use an appropriate electrical filter to eliminate noise to the servo drive.

 

 

 

„ Ensure that the external applied voltage to the drive is correct and matched to the

 

 

 

controller.

 

 

 

„ Ensure that the cables are not damaged, stressed excessively or loaded heavily.

 

 

 

When the motor is running, pay close attention on the connection of the cables and

 

 

 

notice that if they are damaged, frayed or over extended.

 

 

 

„ Check for abnormal vibrations and sounds during operation. If the servo motor is

 

 

 

vibrating or there are unusual noises while the motor is running, please contact the

 

 

 

dealer or manufacturer for assistance.

 

 

 

„ Ensure that all user-defined parameters are set correctly. Since the characteristics

 

Inspection during

 

of various machinery are different, in order to avoid accident or cause damage, do

 

operation

 

not adjust the parameter abnormally and ensure the parameter setting is not an

 

(Control power is

 

excessive value.

 

applied))

 

„ Ensure to reset some parameters when the servo drive is off (Please refer to

 

 

 

Chapter 7). Otherwise, it may result in malfunction.

 

 

 

„ If there is no contact sound or there be any unusual noises when the relay of the

 

 

 

servo drive is operating, please contact your distributor for assistance or contact

 

 

 

with Delta.

 

 

 

„ Check for abnormal conditions of the power indicators and LED display. If there is

 

 

 

any abnormal condition of the power indicators and LED display, please contact

 

 

 

your distributor for assistance or contact with Delta.

English-7

Page 8
Image 8
888 Digital ASDA-A2 manual Basic Inspection, Content