| Servo Drive |
|
| Encoder Cable - Wire Gauge mm2 | (AWG) | |||||
|
| Wire Size |
| Core Number |
| UL Rating |
|
| Standard Wire Length | |
|
|
|
|
|
|
| ||||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) | ||
| 0.13 (AWG26) |
| 10 core (4 pair) |
| UL2464 |
|
| 3m (9.84ft.) |
NOTE | 1) | The boxes ( ) at the ends of the servo drive model names are for optional configurations | ||||
|
| |||||
|
| to the ordering information of the actual purchased product. | ||||
| 2) | Please use shielded | ||||
|
| electrical noise and interference. | ||||
| 3) | The shield of shielded | ||||
|
| marked |
|
|
| ) of the servo drive. |
|
|
|
|
| ||
|
|
|
|
|
Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the AC drive should be stored properly when it is not to be used for an extended period of time. Some storage suggestions are:
Store in a clean and dry location free from direct sunlight.
Store within an ambient temperature range of
Store within a relative humidity range of 0% to 90% and
Do not store in a place subjected to corrosive gases and liquids.
Correctly packaged and placed on a solid surface.
Do not mount the servo drive or motor adjacent to
Do not mount the servo drive or motor in a location subjected to corrosive gases, liquids, or airborne dust or metallic particles.
Do not mount the servo drive or motor in a location where temperatures and humidity will exceed specification.
Do not mount the servo drive or motor in a location where vibration and shock will exceed specification.
Do not mount the servo drive or motor in a location where it will be subjected to high levels of electromagnetic radiation.
Installation Note and Minimum Clearances
Installation Note:
Incorrect installation may result in a drive malfunction or premature failure of the drive and or motor. Please follow the guidelines in this instruction when installing the servo drive and motor.
The AC servo drive should be mounted perpendicular to the wall or in the control panel.
In order to ensure the drive is well ventilated, ensure that the all ventilation holes are not obstructed and sufficient free space is given to the servo drive.
Do not install the drive in a horizontal position or malfunction and damage will occur.