Installation and Storage Conditions

 

Servo Drive

 

 

Encoder Cable - Wire Gauge mm2

(AWG)

 

 

Wire Size

 

Core Number

 

UL Rating

 

 

Standard Wire Length

 

 

 

 

 

 

 

 

ASD-A2-0221-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-0421-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-0721-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-1021-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-1521-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-2023-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

 

ASD-A2-3023-…

0.13 (AWG26)

 

10 core (4 pair)

 

UL2464

 

 

3m (9.84ft.)

NOTE

1)

The boxes (…) at the ends of the servo drive model names are for optional configurations

 

 

(Full-closed loop, CANopen and extension DI port). For the actual model name, please refer

 

 

to the ordering information of the actual purchased product.

 

2)

Please use shielded twisted-pair cables for wiring to prevent voltage coupling and eliminate

 

 

electrical noise and interference.

 

3)

The shield of shielded twisted-pair cables should be connected to the SHIELD end (terminal

 

 

marked

 

 

 

) of the servo drive.

 

 

 

 

 

 

 

 

 

 

Installation and Storage Conditions

The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the AC drive should be stored properly when it is not to be used for an extended period of time. Some storage suggestions are:

„Store in a clean and dry location free from direct sunlight.

„Store within an ambient temperature range of -20̓C to +65̓C (-4̓F to 149̓F).

„Store within a relative humidity range of 0% to 90% and non-condensing.

„Do not store in a place subjected to corrosive gases and liquids.

„Correctly packaged and placed on a solid surface.

„Do not mount the servo drive or motor adjacent to heat-radiating elements or in direct sunlight.

„Do not mount the servo drive or motor in a location subjected to corrosive gases, liquids, or airborne dust or metallic particles.

„Do not mount the servo drive or motor in a location where temperatures and humidity will exceed specification.

„Do not mount the servo drive or motor in a location where vibration and shock will exceed specification.

„Do not mount the servo drive or motor in a location where it will be subjected to high levels of electromagnetic radiation.

Installation Note and Minimum Clearances

Installation Note:

„Incorrect installation may result in a drive malfunction or premature failure of the drive and or motor. Please follow the guidelines in this instruction when installing the servo drive and motor.

„The AC servo drive should be mounted perpendicular to the wall or in the control panel.

„In order to ensure the drive is well ventilated, ensure that the all ventilation holes are not obstructed and sufficient free space is given to the servo drive.

„Do not install the drive in a horizontal position or malfunction and damage will occur.

English-4