Digital Thermometer Instructions – Model DT-103

 

BATTERY

DISPLAY WINDOW

COMPARTMENT

SENSOR TIP

ON/OFF BUTTON

WHAT IS A “NORMAL” TEMPERATURE?

Temperature readings vary among individuals. A normal temperature refers to each individual’s average temperature while they are well. Normal average temperatures range from 97°F/36.1°C to 100°F/37.7°C when taken orally. A rectal temperature is considered your real or “core” body temperature. A rectal temperature is 1°F/0.5°C higher than an oral reading and an underarm temperature is 1°F/0.5°C lower than an oral reading.

HOW TO TAKE TEMPERATURE

1.

Select oral, underarm or rectal as your measurement site (see

 

following instructions).

2.

Push the ON/OFF button. The thermometer will beep and the

 

display will show all symbols. This is a function check indicating

Wash the thermometer as recommended. Approximate measurement time is 40 to 60 seconds.

Once used rectally, the thermometer should not be used orally for sanitary reasons.

CLEANING INSTRUCTIONS

Wash the area extending about 2” from the tip with warm, soapy water after each use and dry thoroughly.

OR

Wipe the area extending about 2” from the tip with 70% isopropyl alcohol after each use.

NOTE: Do not submerge the thermometer in any liquid.

complies with the specifications of the European Standard for clinical thermometers-Part 3:

Performance of compact electrical thermometers (non-predictive and predictive) with maximum device. The CE marking confirms that this is a medical device with a measuring function in the sense of the Medical Devices Act, which has undergone a conformity assessment procedure. A Notified Body confirms that this product fulfills all the appropriate statutory regulations.

COMPLIANCE

Product disposal instructions for electronic devices

Congratulations on your purchase of this A&D Medical Digital Thermometer. Please read the instructions carefully to ensure accurate temperatures and safe operation. When used properly, this high quality product will give you years of accurate, dependable service.

SAFETY INFORMATION

High, prolonged fever requires medical attention (over 100.0°F or 37.8°C) for young children. In case of high readings, please contact your physician.

Do not allow children to take their temperature unattended.

Read the enclosed instructions carefully to ensure accurate temperature readings.

Temperature readings are affected by many factors including exercise, drinking hot or cold beverages prior to taking, and technique.

Do not allow children to walk or run during temperature taking. The rigid probe could present a hazard.

Oral, underarm, and rectal temperatures vary by approxi- mately 1°F (0.5°C).

SPECIAL PRODUCT FEATURES

Memory feature: automatic recall of last temperature reading.

Beeps when peak temperature is reached.

Auto-Off in approximately 10 minutes.

Thermometer is water resistant, but not 100% waterproof. Do not submerge unit in any liquid.

Long-life, replaceable battery (approximately 2,000 temperatures).

Low Battery Indicator “”. Oral, Rectal or Underarm use.

HOW TO CARE FOR THIS PRODUCT

The thermometer should be cleaned after every use even when probe covers are used.

Clean the thermometer tip and probe using isopropyl alcohol or soap and water.

Do not boil the thermometer. Do not submerge the thermometer in any liquid.

Store the unit in the protective case while not in use.

Do not store or keep in direct sunlight, or in high temperatures.

Do not open the thermometer except to replace the battery.

Do not drop the thermometer, as this may break the unit.

Do not attempt to disassemble the unit except to replace the battery.

 

the unit is working properly. If a previous reading is stored in

 

memory, the thermometer will display the last temperature for

 

two seconds. The flashing symbol °F will appear with the “L”

 

or “H” symbol indicating that the thermometer is ready for

 

measurement. Begin measurement.

3.

When the °F symbol stops flashing and the thermometer emits

 

four beeps, the temperature measurement is complete.

4.

Read and record the temperature and time for reference. The

 

reading will automatically be stored in the memory until

 

another reading is taken or the batteries are removed from the

 

thermometer.

5.

Push the ON/OFF button to turn the unit off. If you do not turn

 

the unit off, it will shut off automatically in approximately 10

 

minutes.

ORAL USE

Do not drink hot or cold fluids, exercise, smoke or perform other activities that raise or lower temperature directly prior to taking reading.

The mouth should remain closed up to 5 minutes before attempting a reading.

Place the probe tip well under the tongue in locations as indicated by the “ ” (see

diagram). Instruct children not to bite down on the probe.

The approximate measurement time is 60 seconds. Opening the mouth or improper placement of the probe tip may result in a longer time for a reading.

UNDERARM (AUXILIARY) USE

From a medical point of view, this method will always give an inaccurate reading and should not be used if a precise measurement is required.

Wipe underarm with a dry towel.

Place probe tip in armpit and bring arm

down against the body. The measuring sensor should be pointing upward parallel to the arm.

The approximate measurement time may be 2 minutes or longer depending on the placement of the probe and closure of the arm against the body.

RECTAL USE

Commonly used for babies, young children or when it is difficult to take an oral or underarm temperature.

After placing the probe cover on the thermometer, lubricate with a water-soluble jelly such as K-Y Jelly®.

Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do not force the tip into the rectum if resistance is encountered.

CHANGING THE BATTERY

When the “” appears and blinks, the battery needs to be replaced. Make sure you use the same type of battery and proceed as follows: Remove battery compartment lid. Use a non metal probe to remove battery. Insert new equivalent battery type (1.5V or LR41). Ensure battery is correctly positioned with the “+” facing up. Carefully replace the battery compartment lid. Properly dispose of the battery, keeping it from small children and heat.

CHANGING BETWEEN FAHRENHEIT & CELSIUS

1.This thermometer shows all results in Fahrenheit (F°).

2.To convert results shown in F° to Celsius (C°) use the following equation:

C° = 5/9 x (F°- 32)

3.Here is a helpful chart showing some Fahrenheit and Celsius equivalences:

90.0° 92.0° 94.0° 96.0° 98.0° 100.0° 102.0° 104.0° 106.0° 108.0°

32.2° 33.3° 34.4° 35.6° 36.7° 37.8° 38.9° 40.0° 41.1° 42.2°

SPECIFICATIONS

RANGE. . . . . . . . . . . . . . 89.6°F - 107.6°F (32.0°C - 42.0°C)

ACCURACY MEASUREMENT. . .

± 0.2°F for 95.9°F to 107.6°F

RANGE

± 0.4°F less than 95.9°F

 

± 0.4°F above 107.6°F

 

± 0.1°C for 32.0°C to 42.0°C

 

± 0.2°C less than 32.0°C

 

± 0.2°C above 42.0°C

STORAGE RANGE. . . . . . . . . -13°F to 131°F (-25°C to 55°C)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . when stored ≤ 95% RH

DISPLAY. . . . . . . . . . . . . . 0.1°F (0.1°C)

BATTERY

One 1.5V button size battery

BATTERY LIFE. . . . . . . . . . . Approximately 100 hours of continuous operation

DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . 5.0” x 0.7” x 0.3” (12.7 x 1.8 x 0.8 cm)

WEIGHT. . . . . . . . . . . . . . Approximately 10 grams including battery

LEGAL REQUIREMENTS AND GUIDELINES

This product complies with the European Directive for Medical Devices 93/42/EEC and carries the CE mark. The device also

The battery in this product complies with the requirements stated in European Directives 2006/66/EEC.

Type B equipment

This device conforms to the European Directive 93/42 EEC for Medical Products.

WARRANTY

A&D Medical warrants to the first retail purchaser that this digital thermometer is free from defects in material and workmanship for two years from date of purchase. This warranty does not cover batteries or damage resulting from improper handling or use. To obtain replacement product, please return the product, freight and insurance prepaid, together with proof of purchase and applicable shipping costs to A&D Medical at the address below. Call the toll- free A&D Medical Health Line at 1-888-726-9966 for shipping costs and further information. At A&D Medical’s option, the product will be replaced with a new or refurbished product of equal value. THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. Some states may have laws which amend this warranty.

CONTACT INFORMATION

Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes:

Digital Blood Pressure Monitors

 

Personal Health Scales

 

Manual Blood Pressure Monitors

 

Activity Monitors

 

Blood Pressure Cuffs

 

Digital Thermometers

 

Wireless Products

 

Stethoscopes

 

This A&D blood pressure product is covered by a two year warranty.

Distributed by:

A&D Engineering, Inc.

1756 Automation Parkway San Jose, CA 95131 1-888-726-9966 www.andmedical.com

©2012 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN-DT-103-072012-REV-a

Printed in China

Page 1
Image 1
A&D DT-103 specifications What is a Normal TEMPERATURE?, HOW to Take Temperature, Cleaning Instructions, Compliance