BTR TANK TYPE HEATERS
SERVICE HANDBOOK
A.O. Smith Water Products Service Handbook
Irving, Texas ©2000 Training Department
27
Damper
1234
Black
Red
Yellow
White
Orange Brown Yellow Black
Male Plug
From Heater
21
3
4
Female Plug
EFFIKAL DAMPER
BTR Series 110 and 111 began using the motor open; motor close, Effikal Damper. The
wiring colors from the damper PC Board are different from previous series BTR(C) and
BTC Models.
The heater harness wires still serve the same function:
Service
Switch Adapter
Plug
Heater
Harness
Service
Switch
Motor
Lead
Terminal
Motor
Lead
Motor
Effikal Control Cover (Photo of kit mounting) Effikal Style
Black – 24V Constantif high limit closed
Yellow – 24V To damper if the thermostat is closed
Red – 24V From damper to IID if damper closes end switch
White–Neutral
(
common
)