Pump Sizing for Storage Tank Application
The following applies when using
For recommended pump sizes use the table below. Additional pressure losses in plumbing between the Heater(s) and the storage tank must also be taken into consideration.
The specified pump size is to provide maximum recovery of the storage tank. A smaller pump size may be used, but could result in longer recovery time of the tank. Please contact the Tech Services department with any questions on pump sizing.
NOTE: Only use pumps of brass or stainless steel construction. Do not use pumps of iron
construction as they will oxidize and clog the inlet filter on the appliance.
Pump Flow Requirements
Number of |
|
|
705/505 | 305 | |
Water Heaters |
|
|
|
|
|
1 | 6 gpm @ 30' head | 5 gpm @ 25' head |
|
|
|
2 | 12 gpm @ 30' head | 10 gpm @ 25' head |
|
|
|
3 | 18 gpm @ 30' head | 15 gpm @ 25' head |
|
|
|
4 | 24 gpm @ 30' head | 20 gpm @ 25' head |
|
|
|
5 | 30 gpm @ 30' head | 25 gpm @ 25' head |
|
|
|
6 | 36 gpm @ 30' head | 30 gpm @ 25' head |
|
|
|
7 | 42 gpm @ 30' head | 35 gpm @ 25' head |
|
|
|
8 | 48 gpm @ 30' head | 40 gpm @ 25' head |
|
|
|
9 | 54 gpm @ 30' head | 45 gpm @ 25' head |
|
|
|
10 | 60 gpm @ 30' head | 50 gpm @ 25' head |
|
|
|
11 | 66 gpm @ 30' head | 55 gpm @ 25' head |
|
|
|
12 | 72 gpm @ 30' head | 60 gpm @ 25' head |
|
|
|
13 | 78 gpm @ 30' head | 65 gpm @ 25' head |
|
|
|
14 | 84 gpm @ 30' head | 70 gpm @ 25' head |
|
|
|
15 | 90 gpm @ 30' head | 75 gpm @ 25' head |
|
|
|
| Table “C” |
|