ADMP / ADM / ADMR

Technical specifications

ADM 40

ADM 50

ADM 60

ADM 80

ADM 90

ADM 115

ADM 135

ADMR 40

ADMR 50

ADMR 60

ADMR 80

ADMR 90

ADMR 115

ADMR 135

Gas data natural gas 2H (G20)

Input*

kW

42.2

56.5

66.4

82.5

98.3

126.6

143.4

42.2

56.5

66.4

82.5

98.3

126.6

143.4

Output

kW

32.3

42.8

50.2

62.4

74.3

95.8

109.8

32.3

42.8

50.2

62.4

74.3

95.8

109.8

Inlet pressure

mbar

20

20

20

20

20

20

20

20

20

20

20

20

20

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

8.5

8.5

8.5

8.5

8.5

8.5

11.3

8.5

8.5

8.5

8.5

8.5

8.5

11.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas consumption**

m3/h

4.0

5.4

6.3

7.9

9.4

12.1

13.7

4.0

5.4

6.3

7.9

9.4

12.1

13.7

Diameter main orifice

mm

3.2

3.2

3.1

2.95

3.2

3.2

3.9

3.2

3.2

3.1

2.95

3.2

3.2

3.9

Max. flue gas temperature

°C

180

200

200

180

180

200

185

180

200

200

180

180

200

185

Flue gas discharge

kg/h

121.7

130.2

199.4

190.1

329.0

253.1

302.6

121.7

130.2

199.4

190.1

329.0

253.1

302.6

Gas data butane 3+ (G30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input*

kW

41.6

55.3

68.2

80.7

96.1

123.5

138.4

41.6

55.3

68.2

80.7

96.1

123.5

138.4

Output

kW

32.6

42.8

52.8

62.6

74.5

95.8

108.5

32.6

42.8

52.8

62.6

74.5

95.8

108.5

Inlet pressure

mbar

30

30

30

30

30

30

30

30

30

30

30

30

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas consumption**

kg/h

3.0

4.0

5.0

5.9

7.0

9.0

10.1

3.0

4.0

5.0

5.9

7.0

9.0

10.1

Diameter main orifice

mm

1.7

1.7

1.7

1.5

1.7

1.7

2.25

1.7

1.7

1.7

1.5

1.7

1.7

2.25

Max. flue gas temperature

°C

180

200

200

180

180

200

185

180

200

200

180

180

200

185

Flue gas discharge

kg/h

125.9

129.4

183.9

205.3

344.9

255.6

319.6

125.9

129.4

183.9

205.3

344.9

255.6

319.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas data propane 3+ (G31)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input*

kW

38.4

51.1

63.3

77.7

89.6

113.0

130.1

38.4

51.1

63.3

77.7

89.6

113.0

130.1

Output

kW

30.0

39.5

48.9

60.1

69.2

87.4

101.7

30.0

39.5

48.9

60.1

69.2

87.4

101.7

Inlet pressure

mbar

37

37

37

37

37

37

37

37

37

37

37

37

37

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas consumption**

kg/h

2.7

3.7

4.5

5.6

6.4

8.1

9.3

2.7

3.7

4.5

5.6

6.4

8.1

9.3

Diameter main orifice

mm

1.7

1.7

1.7

1.5

1.7

1.7

2.25

1.7

1.7

1.7

1.5

1.7

1.7

2.25

Max. flue gas temperature

°C

180

200

200

180

180

200

185

180

200

200

180

180

200

185

Flue gas discharge

kg/h

115.2

119.9

177.5

187.4

187.4

239.4

297.1

115.2

119.9

177.5

187.4

187.4

239.4

297.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Draw-off capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage capacity

l

309

357

298

335

278

253

252

309

357

298

335

278

253

252

Max. temperature setting

°C

73

73

73

73

73

73

73

80

80

80

80

80

80

80

30 min. T=44°C

l

621

766

767

914

957

1118

1240

621

766

767

914

957

1118

1240

60 min. T=44°C

l

937

1183

1258

1524

1684

2054

2313

937

1183

1258

1524

1684

2054

2313

90 min. T=44°C

l

1253

1601

1749

2134

2410

2990

3385

1253

1601

1749

2134

2410

2990

3385

120 min. T=44°C

l

1568

2019

2240

2744

3137

3926

4458

1568

2019

2240

2744

3137

3926

4458

Continuous T=44°C

l/h

631

836

982

1220

1453

1872

2145

631

836

982

1220

1453

1872

2145

Heating-up time T=44°C

min.

29

26

18

16

11

8

7

29

26

18

16

11

8

7

30 min. T=50°C

l

547

674

675

805

842

984

1092

547

674

675

805

842

984

1092

60 min. T=50°C

l

824

1041

1107

1341

1482

1808

2035

824

1041

1107

1341

1482

1808

2035

90 min. T=50°C

l

1102

1409

1539

1878

2121

2631

2979

1102

1409

1539

1878

2121

2631

2979

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 min. T=50°C

l

1380

1777

1971

2415

2760

3455

3923

1380

1777

1971

2415

2760

3455

3923

Continuous T=50°C

l/h

556

735

864

1073

1279

1647

1888

556

735

864

1073

1279

1647

1888

Heating-up time T=50°C

min.

33

29

21

19

13

9

8

33

29

21

19

13

9

8

30 min. T=55°C

l

497

612

614

732

766

895

992

497

612

614

732

766

895

992

60 min. T=55°C

l

749

947

1006

1219

1347

1643

1850

749

947

1006

1219

1347

1643

1850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 min. T=55°C

l

1002

1281

1399

1707

1928

2392

2708

1002

1281

1399

1707

1928

2392

2708

120 min. T=55°C

l

1255

1615

1792

2195

2509

3141

3566

1255

1615

1792

2195

2509

3141

3566

Continuous T=55°C

l/h

505

669

785

976

1162

1497

1716

505

669

785

976

1162

1497

1716

Heating-up time T=55°C

min.

37

32

23

21

14

10

9

37

32

23

21

14

10

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

W

30

30

30

30

30

30

60

50

50

50

50

50

50

80

Power supply

VAC/Hz

 

 

230 (-15 / +10%) / 50

 

 

 

230 (-15 / +10%) / 50 (+/- 1 Hz)

 

General

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anodes

-

2

2

2

3

3

4

4

2

2

2

3

3

4

4

Maximum working pressure

bar

 

 

 

8

 

 

 

 

 

 

8

 

 

 

Maximum weight

kg

504

578

507

573

522

523

581

504

578

507

573

522

523

581

Shipping data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight empty

kg

195

221

209

238

244

270

329

195

221

209

238

244

270

329

Weight incl. packaging

kg

214

242

230

259

265

291

350

214

242

230

259

265

291

350

Width packaging

mm

780

780

780

780

780

780

910

780

780

780

780

780

780

910

Height packaging

mm

1930

2140

1930

2140

1975

2045

2050

1930

2140

1930

2140

1975

2045

2050

Depth packaging

mm

870

870

870

870

870

870

910

870

870

870

870

870

870

910

*Gas data on gross value

**Gas consumption at 15°C and 1013.25 mbar

Page 2
Image 2
A.O. Smith ADMR - 60, ADMR - 80, ADMR - 90, ADMR - 50, ADMP - 80 manual Technical specifications, Gas data natural gas 2H G20

ADMR - 90, ADMP - 90, ADMR - 115, ADMP - 50, ADMP - 115 specifications

A.O. Smith is a well-respected name in the water heater industry, known for its commitment to providing high-quality and energy-efficient products. Among its extensive range, the ADMR and ADMP series stand out for their advanced technologies and impressive specifications. The models ADMR - 50, ADMP - 80, ADMR - 40, ADMP - 115, and ADMR - 80 showcase the brand's dedication to innovation and consumer satisfaction, making them ideal choices for residential and commercial applications.

The ADMR - 50 model offers a 50-gallon capacity, perfect for medium-sized homes. It features a high-efficiency design that not only saves energy but also delivers hot water consistently. The unit employs a smart electronics system that optimizes performance by adjusting the energy input based on the usage pattern, ensuring that users have hot water when needed.

The ADMP - 80 model boasts an 80-gallon capacity and is ideal for larger households or businesses. This model is equipped with a state-of-the-art condensing technology, which improves efficiency by recovering heat that would otherwise be lost. The result is an impressive Energy Factor rating that can significantly reduce energy costs over time.

For those requiring a smaller solution, the ADMR - 40 offers a 40-gallon capacity, making it suitable for smaller families or apartments. Like its larger counterparts, this model features advanced insulation to minimize heat loss. The durable construction and user-friendly interface enhance its appeal, ensuring that maintenance and operation are straightforward.

The ADMP - 115 takes high-capacity to the next level with an impressive 115-gallon capacity, making it suitable for commercial applications or large households. Its enhanced heating capacity allows for a higher flow rate of hot water, which is crucial during peak usage times. Additionally, the unit's integrated smart technology helps to monitor usage and optimize performance accordingly.

Lastly, the ADMR - 80 combines the features of the ADMR series with an 80-gallon tank size, offering a balance between capacity and efficiency. Its dual heating elements guarantee quick recovery times, ensuring that hot water is always available for multiple needs simultaneously.

Overall, A.O. Smith’s ADMR and ADMP series are engineered with cutting-edge technologies and characteristics designed to enhance performance and efficiency in various settings. With impressive capacities and innovative features, these models cater to a wide array of residential and commercial water heating needs, making them a top choice for consumers seeking reliability and efficiency in their hot water solutions.