A.O. Smith BT- 65 warranty Rough-In-Dimensions, Foreword, Recovery Capacities

Models: BT- 65

1 16
Download 16 pages 62.28 Kb
Page 2
Image 2
ROUGH-IN-DIMENSIONS

ROUGH-IN-DIMENSIONS

DIMENSIONS

Model

 

A

B

C

D

E

F

G

H

J

BT-65

In.

63 1/2

61

26

22

4

8

3/4

1/2

53 3/4

mm

1613

1550

660

559

106

203

NPT

NPT

1,365

 

 

 

 

 

 

 

 

 

 

 

 

RECOVERY CAPACITIES

 

 

 

 

 

 

 

 

 

 

 

RECOVERY CAPACITIES

 

 

 

 

 

 

 

 

 

 

 

 

U.S. Gallons/Hrs. and Litres/Hr. at TEMPERATURE RISE INDICATED

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

Input

Approx.

20F°

30F°

40F°

50F°

60F°

70F°

80F°

90F°

100F°

110F°

120F°

130F°

140F°

Model

Gas

Btuh

KW

Capacity

11C°

17C°

22C°

28C°

33C°

39C°

44°C

50C°

56C°

61C°

67C°

72C°

78C°

BT-65

Natural

65,000

 

65 US Gals.

GPH

299

200

150

120

100

86

75

67

60

54

50

46

43

 

19.0

246 Litres

LPH

1133

756

567

453

378

324

283

252

227

206

189

174

162

 

 

 

BT-65

Propane

55.000

 

65 US Gals.

GPH

253

169

127

101

84

72

63

56

51

46

42

39

36

 

16.1

246 Litres

LPH

959

639

479

384

320

274

240

213

192

174

160

48

137

 

 

 

FOREWORD

The design of Model BT-65 complies with the latest version of ANSI Z21.10.1/CSA 4.1 M98 as automatic storage type water heater.

Installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping necessary. It is highly essential that all water and gas piping be installed as shown on the diagrams.

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction

should be consulted before installations are made.

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the latest editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, in Canada CAN/CSA B 149.1-00. Both are available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131. For Canadian customers, 178 Rexdale Blvd., Rexdale (Toronto), Ontario, Canada M9W 1R3. The National Fuel Gas Code, ANSI Z223.1/NFPA 54 is available from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.