FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED AT FAUCETS.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING: smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push down or turn the gas control knob. Never use tools. If the knob will not push down or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

LIGHTING INSTRUCTIONS

GAS CONTROL

TOP VIEW

FIGURE “D”

1.STOP! Read the safety information above on this label.

2.Set the thermostat to the lowest setting by turning thermostat dial fully clockwise until it stops.

3.Push the gas control knob down slightly and turn

clockwise to "OFF". (Figure A).

NOTE: Gas control knob CANNOT be turned from "PILOT" to "OFF" unless it is pushed down slightly. Do not force.

4.Remove the inner and outer burner doors located below and behind the gas control unit.

5.Wait five (5) minutes to clear out any gas. If you then

smell gas

STOP! Follow "B" in the

safety

information

above on this label. If you

do not

smell gas, go to the next step.

6.Find Pilot: Follow metal tube from the bottom , right of the gas control to the pilot burner. (Figure D).

7.Turn gas control knob counterclockwise to "PILOT". (Figure B).

8.Push gas control knob down all the way and hold it

down. Immediately light the pilot with a match. Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out, repeat Steps 3 through 8. It may take several minutes for air to clear the lines, before the pilot will light.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" (Figure A) and call your service technician or gas supplier.

9.Replace inner and outer burner doors.

10.At arm's length away, turn gas control knob

counterclockwise to on. (Figure C).

11.Set thermostat to desired setting (See Figure).

CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting.

2.Push the gas control knob down slightly and turn clockwise to "OFF". (Figure A). Do not force.

11

Page 11
Image 11
A.O. Smith BT- 80 warranty For Your Safety Read Before Lighting, What to do if YOU Smell GAS

BT- 80 specifications

A.O. Smith BT-80 is a notable model in the realm of water heater technology, representing a confluence of efficiency, durability, and advanced engineering. As an industry leader, A.O. Smith has designed this model with the end-user in mind, focusing on delivering a reliable and long-lasting water heating solution suitable for residential and light commercial applications.

One of the standout features of the BT-80 is its impressive 80-gallon capacity, which makes it ideal for households with high hot water demands. Whether it's for daily showers, laundry, or dishwashing, this water heater can accommodate the needs of larger families or homes that require a consistent supply of hot water throughout the day.

The BT-80 utilizes a high-efficiency burner that maximizes energy use, ensuring that less fuel is consumed while providing consistent heating performance. This feature not only reduces utility costs for the homeowner but also reinforces A.O. Smith's commitment to environmentally friendly solutions. Additionally, the water heater is equipped with an insulated tank that minimizes heat loss, further improving its efficiency.

Safety and reliability are key characteristics of the BT-80. It comes with advanced safety features, including a pressure relief valve that prevents excess pressure build-up, ensuring safe operation at all times. The product is also designed for easy maintenance, with accessibility features that allow users or technicians to perform routine checks and repairs conveniently.

This model incorporates cutting-edge technology such as the company's Blue Diamond® glass coating, which provides superior corrosion resistance. This protective feature extends the lifespan of the tank, making it an excellent investment for homeowners.

Moreover, the BT-80 is built to meet stringent industry standards, ensuring it not only performs well but also complies with local codes. Its robust construction means it can withstand various water conditions while maintaining efficiency.

In summary, the A.O. Smith BT-80 is an exemplary water heating solution characterized by its large capacity, energy-efficient operation, advanced safety features, and durable design. It is an ideal choice for customers seeking a reliable and efficient way to meet their hot water needs. With A.O. Smith's reputable engineering and commitment to quality, the BT-80 is a worthy consideration for anyone in the market for a new water heater.