WARNING

VENT HOOD(S) MAY BE

EXTREMELY HOT

DURING OPERATION.

FIGURE 3

REFER TO FIG. 1 FOR CONNECTION DETAILS. BEFORE ATTACHING THE GAS LINE BE SURE THAT ALL GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORATED IN THE PIPING, FIGURE 1. The dirt leg must be readily accessible. Install in accordance with recommendations of serving gas supplier. Refer to the current edition of ANSI Z223.1.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to thermostat gas inlet. The thermostat inlet has a pad for use with a backup wrench.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads. Use compounds resistant to the action of liquefied petroleum gases. Do not use teflon tape on thermostat fittings.

CONNECTION OF GAS PIPE

1.When connecting gas pipe to unit, apply wrench to flange only. Note: Do not use wrench on gas valve or gas valve bracket.

2.PERFORM THE GAS LEAK TEST ANY TIME WORK IS DONE ON A GAS SYSTEM TO AVOID THE POSSIBILITY OF FIRE OR EXPLOSION WITH PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

The Gas Leak Test is performed as follows: Paint pipe connections upstream of gas control with a rich soap and water solution to test for leaks before operating main burner. Bubbles indicate gas leak. To stop leak, tighten pipe connections. After piping connections are checked, turn on main burner. (See Lighting and Operating Instructions in this manual or on water heater.) With main burner in operation, paint pipe joints (including flanges), and control inlet and outlet with rich soap and water solution. Bubbles indicate gas leak. To stop leak, tighten

flange screws, joints and pipe connections. Replace part if leak can't be stopped.

DISCONNECT THE APPLIANCEAND ITS INDIVIDUAL SHUT OFF VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2 PSI (3.5 kPa).

GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES AT 1/2 PSI (3.5 kPa) OR LESS, THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST BY CLOSING THE MAIN MANUAL GAS VALVE.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. USE SOAP AND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE. DO NOT USE MATCHES CANDLES, FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS.

RELIEF VALVE

A NEW TEMPERATURE AND PRESSURE RELIEF VALVE COMPLYING WITH THE STANDARD FOR RELIEF VALVES AND AUTOMATIC GAS SHUT OFF DEVICES FOR HOT WATER SUPPLY SYSTEMS, ANSI Z21.22 (CURRENT EDITION) MUST BE INSTALLED IN THE HEATER IN THE MARKED OPENING PROVIDED. THE VALVE MUST BE OF A SIZE (INPUT RATING) THAT WILL BE ADEQUATE FOR YOUR SIZE HEATER.

Check the metal tag on the relief valve and compare it to the heater’s rating plate. The pressure rating of relief valve must not exceed the working pressure shown on the rating plate of the heater. In addition the hourly Btu rated temperature steam discharge capacity of the relief valve shall not be less than the input rating of the heater. NO VALVE IS TO BE PLACED BETWEEN THE RELIEF VALVE AND TANK. DO NOT PLUG THE RELIEF VALVE.

7

Page 7
Image 7
A.O. Smith BTX-80 warranty Connection of GAS Pipe, Relief Valve

BTX-80 specifications

The A.O. Smith BTX-80 is a high-efficiency water heater designed to meet the needs of both residential and light commercial applications. Engineered with the latest technology, this unit promises reliability and superior performance, making it a standout choice for those seeking an efficient hot water solution.

One of the primary features of the BTX-80 is its energy efficiency. With a high Energy Factor (EF) rating, this water heater is designed to minimize energy consumption while delivering reliable hot water. This feature not only helps owners save on utility bills but also contributes to a more sustainable living environment.

The BTX-80 utilizes advanced condensing technology, allowing it to extract heat from exhaust gases that would typically be expelled. This process enhances its efficiency and reduces the amount of fuel needed to heat water, ensuring that users benefit from lower operating costs. The unit comes equipped with a built-in power vent system, which allows for flexible installation options and an easy, straightforward setup.

Another notable characteristic of the A.O. Smith BTX-80 is its robust build quality. Designed with durable materials, it features a glass-lined tank that helps prevent rust and corrosion, extending the lifespan of the unit. The BTX-80 is also equipped with advanced insulation, which ensures minimal heat loss and improved energy retention.

Safety features are paramount when it comes to water heating, and the BTX-80 does not disappoint. It includes a fully integrated safety system that protects against overheating and excessive pressure, ensuring peace of mind for homeowners and business operators alike.

Additionally, the BTX-80 has a user-friendly digital display and diagnostic control system, allowing users to easily monitor and adjust settings. It also features multiple installation configurations to adapt to various space requirements.

In summary, the A.O. Smith BTX-80 water heater combines high energy efficiency, advanced condensing technology, robust construction, and user-friendly features. Ideal for those seeking a reliable and sustainable hot water solution, this model is a testament to A.O. Smith's commitment to innovation and quality in the water heating industry.