Image 2
ROUGH-IN DIMENSIONS

ROUGH-IN DIMENSIONS

* NO SIDE OUTLET AVAILABLE FOR DEL 6 MODELS

ROUGH-IN DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

Models

No. of

Tank Capacity

 

A

 

B

 

C

 

D

Shipping Weight.

Dimensions

Elements

US Gals.

Litres

inches

 

mm

inches

 

mm

inches

 

mm

inches

 

mm

Lbs.

 

Kg.

DEL-6

1

6

23

15 1/2

 

394

14 1/4

 

362

11

 

279

-

 

-

35

 

15.9

DEL-10

1

10

38

18 1/4

 

464

18

 

457

12 1/2

 

318

-

 

-

54

 

24.5

DEL-15

1

15

57

26

 

660

18

 

457

20 1/2

 

521

-

 

-

58

 

26.3

DEL-20

1

20

76

22 1/4

 

565

21 3/4

 

552

15 3/8

 

391

-

 

-

73

 

33.1

DEL-30

2

30

114

30 7/8

 

784

21 3/4

 

552

24 1/8

 

613

8

 

203

100

 

45.4

DEL-40

2

40

151

32 1/4

 

819

24

 

610

25 9/16

 

649

8

 

203

125

 

56.7

DEL-50

2

50

189

32 1/4

 

819

26 1/2

 

673

25 1/8

 

638

8

 

203

166

 

75.3

DEN-30

1

30

114

34 1/2

 

876

20 1/2

 

521

-

 

-

8

 

203

98

 

44.5

DEN-40

2

40

151

45 1/8

 

1146

20 1/2

 

521

-

 

-

8

 

203

113

 

51.3

DEN-52

2

50

189

54 7/8

 

1394

20 1/2

 

521

-

 

-

8

 

203

131

 

59.4

DEN-66

2

66

250

60 3/4

 

1543

21 3/4

 

552

-

 

-

8

 

203

176

 

79.8

DEN-80

2

80

303

59 3/8

 

1508

24

 

610

-

 

-

8

 

203

211

 

95.7

DEN-120

2

119

450

62 7/16

 

1586

29 3/8

 

746

-

 

-

8

 

203

326

 

147.9

RECOVERY CAPACITIES

Element

 

 

 

 

 

U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED

Wattage

INPUT

 

36F°

40F°

 

54F°

60F°

72F°

80F°

90F°

100F°

108F°

120F°

126F°

 

(Upper/Lower)

KW

 

20C°

22.2C°

 

30C°

33.3C°

40C°

44.4C°

50C°

55.5C°

60C°

66.6C°

70C°

NON-SIMULATANEOUS OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

/1500

 

GPH

 

17

15

 

11

10

8

8

7

6

6

5

5

 

 

1.5

LPH

 

64

58

 

43

38

32

29

26

23

21

19

18

 

/2000

 

GPH

 

23

20

 

15

14

11

10

9

8

8

7

6

 

 

2.0

LPH

 

85

77

 

57

51

43

38

34

31

28

26

24

 

/2500

 

GPH

 

28

25

 

19

17

14

13

11

10

9

8

8

 

 

2.5

LPH

 

107

96

 

71

64

53

48

43

38

36

32

30

 

3000/3000

 

GPH

 

34

30

 

23

20

17

15

14

12

11

10

10

 

 

3.0

LPH

 

128

115

 

85

77

64

58

51

46

43

38

37

 

4000/4000

 

GPH

 

45

41

 

30

27

23

20

18

16

15

14

13

 

 

4.0

LPH

 

170

153

 

114

102

85

77

68

61

57

51

49

 

4500/4500

 

GPH

 

51

46

 

34

30

25

23

20

18

17

15

14

 

 

4.5

LPH

 

192

173

 

128

115

96

86

77

69

64

58

55

 

5000/5000

 

GPH

 

56

51

 

38

34

28

25

23

20

19

17

16

 

 

5.0

LPH

 

213

192

 

142

128

107

96

85

77

71

64

61

 

6000/6000

 

GPH

 

68

61

 

45

41

34

30

27

24

23

20

19

 

 

6.0

LPH

 

256

230

 

170

153

128

115

102

92

85

77

73

 

SIMULATANEOUS OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

3000/3000

 

GPH

 

68

61

 

45

41

34

30

27

24

23

20

19

 

 

6

LPH

 

256

230

 

170

153

128

115

102

92

85

77

73

 

4000/4000

 

GPH

 

90

81

 

60

54

45

41

36

32

30

27

26

 

 

8

LPH

 

341

307

 

227

205

170

153

136

123

114

102

97

 

4500/4500

 

GPH

 

101

91

 

68

61

51

46

41

36

34

30

29

 

 

9

LPH

 

384

345

 

256

230

192

173

153

138

128

115

110

 

5000/5000

 

GPH

 

113

101

 

75

68

56

51

45

41

38

34

32

 

 

10

LPH

 

426

384

 

284

256

213

192

170

153

142

128

122

 

6000/6000

 

GPH

 

135

122

 

90

81

68

61

54

49

45

41

39

 

 

12

LPH

 

511

460

 

341

307

256

230

205

184

170

153

146

 

Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation

=4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single phase = total watts : voltage.

2

Page 2
Image 2
A.O. Smith DEN, DEL warranty Rough-In Dimensions, Recovery Capacities