dimensions and capacities data
DRE/DVE MODEL DIFFERENCES
This Instruction Manual covers two models of commercial electric water heaters; DRE models and DVE models. These two models are equipped from the factory with different controls.
DRE models are factory equipped with surface mounted thermostat/ECO combination controls. DVE models are factory equipped with an electronic control system.
In this Instruction Manual “DRE” models are referred to as: “Surface Mount Control” models.
In this Instruction Manual “DVE” models are referred to as: “Electronic Control” models.
Model Number | Tank Capacity in Gallons (Liters) | A - Inches (mm) | B - Inches (mm) | C - Inches (mm) | Inlet/Outlet |
|
|
|
|
|
|
50 (189.3) | 55 3/4 (1416) | 21 3/4 (552) | 27 (685) | 1 1/4 | |
80 (302.8) | 60 1/4 (1350) | 25 1/2 (648) | 31 (787) | 1 1/4 | |
119 (450.5) | 62 1/4 (1581) | 29 1/2 (749) | 35 (889) | 1 1/4 |
RECOVERY RATE IN GALLONS PER HOUR*
Temperature Rise °F
Standard | BTU/ |
|
|
|
|
|
|
|
|
|
|
|
|
KW Input | Hour | 30° | 40° | 50° | 60° | 70° | 80° | 90° | 100° | 110° | 120° | 130° | 140° |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | 20,478 | 82 | 62 | 49 | 41 | 35 | 31 | 27 | 25 | 22 | 21 | 19 | 18 |
9 | 30,717 | 123 | 92 | 74 | 62 | 53 | 46 | 41 | 37 | 34 | 31 | 28 | 26 |
12 | 40,956 | 164 | 123 | 98 | 82 | 70 | 61 | 55 | 49 | 45 | 41 | 38 | 35 |
13.5 | 46,075 | 184 | 138 | 111 | 92 | 79 | 69 | 62 | 55 | 50 | 46 | 43 | 40 |
15 | 51,195 | 205 | 154 | 123 | 102 | 88 | 77 | 68 | 61 | 56 | 51 | 47 | 44 |
18 | 61,434 | 246 | 184 | 148 | 123 | 105 | 92 | 82 | 74 | 67 | 61 | 57 | 53 |
24 | 81,912 | 328 | 246 | 197 | 164 | 140 | 123 | 109 | 98 | 89 | 82 | 76 | 70 |
27 | 92,151 | 369 | 276 | 221 | 184 | 158 | 138 | 123 | 111 | 101 | 92 | 85 | 79 |
30 | 102,390 | 410 | 307 | 246 | 205 | 176 | 154 | 137 | 123 | 112 | 102 | 95 | 88 |
36 | 122,868 | 492 | 369 | 295 | 246 | 211 | 184 | 164 | 148 | 134 | 123 | 113 | 105 |
40.5 | 138,226 | 554 | 418 | 3332 | 277 | 237 | 208 | 1185 | 166 | 151 | 138 | 128 | 119 |
45 | 153,585 | 615 | 461 | 369 | 307 | 263 | 230 | 205 | 184 | 168 | 154 | 142 | 132 |
54 | 184,302 | 738 | 553 | 443 | 369 | 316 | 277 | 246 | 221 | 201 | 184 | 170 | 158 |
*Figured at 1 KW (3413 Btu) = 4.1 gallons at 100°F temperature rise.
To determine recovery rate per minute, divide recovery rate per hour by 60.