is
Instruction manual GWV 83
Code + description Cause Measures to take Comment
C02 (lock out error)
Error message from the
appliance controller.
Incorrect reference
voltage from the AD
converter.
1. Reset electronic controller.
2. Check that the frequency of the power supply is
compliant (3.4.2 "General and electrical specifications"). If this
is not the case, contact your installation engineer
3. If the frequency is correct but the error persists, replace the
electronic controller.
To replace the necessary parts, you must contact your installation
engineer
Internal error message
from the appliance
controller.
EEPROM read
error
50 Hz error
Internal
communication
error
Internal error message
from the appliance
controller.
Gas valve relay
error
Safety relay error
Ignition relay error
RAM error
EEPROM error
EEPROM contents
do not match the
software version
Processor software
error
C04 (blocking error)
Appliance selection
error
Incorrect appliance
selection / Incorrect
selection resistor
1. Check whether the correct appliance is
selected(12.5 "Displaying the applia nce selection").
2. If the correct appliance is selected, fit the correct selection
resistor.
3. If incorrect appliance selected, select the correct one.
If the error cannot be resolved or is persistent, contact your
installation engineer
To replace the necessary parts, you must contact your installation
engineer