RESIDENTIAL GAS AND ELECTRIC WATER HEATER Complaint: No Hot Water Conditions: Voltage Checks Test voltage between 1 and 3 or L1 and L3 of high limit. If … … then Test voltage between 2 and 4 or L1 and L4 of high limit Test voltage between 4 and 2 or T2 and L4
SERVICE HANDBOOK
Residential Electric – continued
C-2 – service continued
Tank water cold
Power on
Procedure: Multimeter set for
AC voltage check
rated voltage is not present • check circuit breaker (fused disconnect)
• check wire connections in heater junction
box
• check position of heater ON/OFF switch-if
applicable.
rated voltage is present continue to next step.
If … … then
rated voltage is not present • press high limit reset button
• replace high limit (after conducting
thermostat check)
rated voltage is present continue to next step.
If … … then
rated voltage is not present • check jumper between high limit 2 and
thermostat 1or
• on T2, L4 test-replace control.
rated voltage is present continue to next step.
A.O. Smith Water Products Company Technical Training Department
©2005 Ashland City, TN