OPERATING INSTRUCTIONS

Step 4 Remove the glass completely. Store glass- retaining clips and white gasket (if sound) safely for re-use.

Step 5 Follow this procedure in reverse to fit replacement door glass or gasket.

GLASS

GLASS CLIP

GASK ET

FIRE DOOR

Fig. 6

DOOR ADJUSTMENT

The catch can be adjusted by sharply tapping the catch on the inside of the door.

Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture or catch on the door interlock mechanism. This is quite normal and due to the settling of the casing.

The fire door can be re-aligned by the user as follows:

•When the appliance is cold, open the fire door so that it is at a right angle to the front face of the fire.

•Lift the fire door up off the hinges.

•Gently tap the two hinge pins in a direction to compensate for the misalignment.(fig 7)

Fig. 7

•Refit the door and check to ensure it now sits square to the body; if not repeat above steps.

Raising the door as follows:

•When the appliance is cold, open the fire door so that it is at a right angle to the front.

•Lift the fire door up off the hinges.

•Drop one washer on the top and bottom hinge pin.

•Refit the door and check to ensure door is free of the interlock. If not remove and repeat fitting second washer.

FUEL RETAINER BARS

Fuel retainer bars are supplied with the fires.

For wood burning, 1 fuel retainer bar is used, affording a better view of the fire. Slide and lift the bar until it is clear of the guides at each side, and remove through the fire door opening.

The bars are symmetrical and of even lengths making incorrect fitting impossible.

Note: This operation should only be carried out when the appliance is unlit and cold.

10

Stratford Tf & Ti Multifuel Boiler Stoves

Page 10
Image 10
Aarrow Fires Tf 70 installation manual Operating Instructions, Door Adjustment, Fuel Retainer Bars