Baud Rate Ranges

The card has capability for two baud rate ranges and you can select which you wish to use on a port-by-port basis. One range is for up to 115,200 baud applications and the other is up to 460,800 baud applications.

Specifications

Communications Interface

I/O Connection:

9-pin D-sub connectors

Serial Ports:

Four shielded male D-sub 9-pin IBM AT style connectors

 

 

compatible with RS422 specifications. (Note: On model an

 

 

external "spider" or breakout cable terminates with four female

 

 

D-sub 9-pin connectors.)

Character length:

5, 6, 7, or 8 bits.

Parity:

Even, odd or none.

Stop Interval:

1, 1.5, or 2 bits.

Serial Data Rates:

Up to 115,200 baud, Asynchronous, A faster range of rates up

 

 

to 460,800, is achieved by jumper selection on the card. Type

 

 

16550 buffered UART.

Address:

Continuously mappable within 0000 to FFFF (hex) range of PCI

 

 

bus addresses (Conforms to PCI Specification 2.1).

Receiver Input Sensitivity:

±200 mV, differential input.

Common Mode Rejection:

+12V to -7V

• Transmitter Output Drive Capability:

60 mA, with thermal shutdown.

Environmental

Operating Temperature Range:

0 °C. to +60 °C.

Storage temperature Range:

-50 °C. to +120 °C.

Humidity:

5% to 95%, non-condensing.

Size:

6.1" long (155 mm) by 3.9" (99 mm).

Power Required:

+5VDC at 125 mA typical, -12VDC at 5 mA typical, +12VDC at

 

 

5 mA typical, 750 mW total power consumption.