ACCO Brands GLM11, GLHS9 Troubleshooting, Reposition Shredder Head, Check Motor Input Voltage

Models: GLM11 REXEL GLHS9 GLX20 GBC GLS28

1 13
Download 13 pages 49.68 Kb
Page 8
Image 8
Troubleshooting

 

 

Troubleshooting

5

 

 

 

 

 

 

 

Shredder Does Not

Power Cord Disconnected.

Connect Power Cord

Operate, No Indication Of

Powerswitch Defective

Replace Power Switch

Power

 

 

Main Board Defective

Replace Main Board

Shredder Does Not

Shredder Head Not

Reposition Shredder Head

Operate, With Indication

Installed Properly

 

Of Power Present

Cabinet Door Open

Close Door

 

 

Shred Bag Full

Empty Bag

 

Motor Thermal Cut

Allow Motor To Cool

 

Triggered

 

 

Door Switch Defective

Replace Door Switch

Shredder Does Not

Defective Capacitor

Replace Capacitor

Operate, (When Paper Is

Motor Defective

Check Motor Input Voltage

Present In The Throat)

 

 

Replace Motor If Necessary

 

Emitter/Receiver Defective

Replace If Necessary

 

Main Board Defective

Replace If Necessary

Shredder Runs

Dust Or Scratch On

Clean Or Replace

Continuously

Emitter/Receiver

 

 

Defective Control Board

Replace If Necessary

 

Emitter/Receiver Defective

Replace If Necessary

Sheet Capacity

Dry Blades

Lubricate Cutters

Diminished

 

Dull Cutters

Replace Cutters

 

Worn Bearings

Replace Bearings