Accton Technology Specifications, EtherHub-16 Quick Start Guide, Symptom, Causes, Solution

Models: 16

1 10
Download 10 pages 27.48 Kb
Page 6
Image 6
Symptom:

 

 

EtherHub-16 Quick Start Guide

Symptom:

Jabber indicator lights up.

Causes:

Frame received on this port exceeds length threshold for Jabber Lockup Protection.

Solution:

If jabber lockup has occurred, it will be automatically re-enabled when the problem

 

is corrected or the port receives a valid data packet. Check for a faulty network

 

interface card that has started transmitting data but never stops.

Symptom:

Power indicator does not light up after power on.

Causes:

Defective power supply or attached cable, or a problem at the power source.

Solution:

Check the power source and attached cable. If the problem cannot be resolved, you

 

may have to replace your unit’s power supply. Ask for dealer assistance.

Specifications

 

Transmission Technique

: Baseband

Topology

 

: Tree, Star, Bus (BNC)

Access Method

: CSMA/CD, 10 Mbps

Standard Conformance

: IEEE 802.3 10BASE-T

Media Supported

: Category 3,4,5 twisted-pair cable

Interfaces

 

: 16 standard MDI-X RJ-45 ports, 1 MDI RJ-45 daisy-chain port,

 

 

2 AUI ports, 2 BNC ports

Hub-to-Workstation Distance

: 100m max.

DimensionsDimensions

: 442mm x 141mm x 50mm (17.4" x 5.55" x 1.97")

Power Input

 

: 100-240 (ô10%) VAC

Power Consumption

: 1 Amp max.

Temperature

 

: 0°C to 80°C (Standard Operating)

Humidity

 

: 90% (Noncondensing)

Certification

 

:

Emissions

: FCC Class A

Safety

: UL, CSA, TÜV/GS

6

Page 6
Image 6
Accton Technology quick start Specifications, EtherHub-16 Quick Start Guide, Symptom, Causes, Solution