EtherHub-24s

Safety Compliance

Underwriters Laboratories Inc. (USA)

Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list.

Voltage

Cord Set Specifications

120 Volts

UL Listed/CSA Certified Cord Set

 

Minimum 18 AWG; type SVT or SJT three conductor cord

 

Maximum length of 15 feet

 

Parallel blade, grounding type attachment plug rated 15A, 125V

240 Volts

UL Listed/CSA Certified Cord Set

(North America)

Minimum 18 AWG; type SVT or SJT three conductor cord

 

Maximum length of 15 feet

 

Tandem blade, grounding type attachment plug rated 15A, 125V

240 Volts

Cord Set with H05VV-F cord having three conductors with

(Europe only)

minimum diameter of 0.75 mm²

 

IEC-320 receptacle; male plug rated 10A, 250V

Wichtige Sicherheitshinweise (Germany)

1.Bitte lesen Sie diese Hinweise sorgfältig durch.

2.Heben Sie diese Anleitung für den späteren Gebrauch auf.

3.Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung.

4.Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein.

5.Das Gerät ist vor Feuchtigkeit zu schützen.

6.Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen könnte Beschädigungen hervorrufen.

7.Die Belüftungsöffnungen dienen der Luftzirkulation, die das Gerät vor Überhitzung schützt. Sorgen Sie dafür, daß diese Öffnungen nicht abgedeckt werden.

8.Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte.

9.Verlegen Sie die Netzanschlußleitung so, daß niemand darüber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden.

10.Alle Hinweise und Warnungen, die sich am Gerät befinden, sind zu beachten.

11.Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden.

12.Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen.

13.Öffnen sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.

14.Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen:

a.Netzkabel oder Netzstecker sind beschädigt.

b.Flüssigkeit ist in das Gerät eingedrungen.

c.Das Gerät war Feuchtigkeit ausgesetzt.

d.Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen.

e.Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.

f.Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.

15.Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter als H05VV-F, 3G, 0.75mm2 einzusetzen.

Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70dB(A) oder weniger.

Quick Installation Guide

Warranty

Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for three years. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices. The warranty does not cover the product if it is damaged in the process of being installed.

THEABOVE WARRANTY IS IN LIEU OFANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TOANY WARRANTY OF MERCHANTABILITY, FITNESS FORA PARTICULAR PURPOSE, OR ANYWARRANTY ARISING OUT OFANY PROPOSAL, SPECIFICATION OR SAMPLE. ACCTON SHALL NOT BE LIABLE FOR INCIDENTALOR CONSEQUENTIAL DAMAGES. ACCTON NEITHERASSUMES NORAUTHORIZESANY PERSON TOASSUME FOR ITANY OTHER LIABILITY.

8

9

Page 7
Image 7
Accton Technology 24S EtherHub-24s Safety Compliance, Quick Installation Guide Warranty, Voltage Cord Set Specifications

24S specifications

Accton Technology, a prominent player in the networking and telecommunications industry, has introduced the 24S, an advanced Ethernet switching system designed to cater to the increasing demands of modern networking environments. This product stands out for its robust features, cutting-edge technologies, and exceptional performance characteristics, making it an ideal choice for businesses and data centers seeking reliable networking solutions.

The 24S is equipped with 24 high-speed Ethernet ports that support a range of connectivity options. These ports are capable of delivering speeds up to 10 Gbps, providing ample bandwidth for data-intensive applications and ensuring seamless connectivity for a multitude of devices. With a focus on scalability, the 24S can easily accommodate growing network requirements, making it suitable for both small and large enterprises.

One of the standout features of the Accton Technology 24S is its support for advanced Layer 2 and Layer 3 switching capabilities. This allows for efficient traffic management and optimized data flow through the network. The switch offers advanced routing features, including support for Static Routing, RIP, and OSPF, which enhance the ability to manage complex network architectures.

The 24S is also built with redundancy and reliability in mind. It includes powers supply options that ensure uninterrupted operation even in the event of power failures. Furthermore, the switch features hot-swappable components, allowing for easy upgrades and maintenance without downtime, which is critical in mission-critical environments.

Security is another priority for the 24S. The switch comes with built-in security features that include VLAN support, Access Control Lists (ACLs), and DHCP Snooping. These features provide enhanced protection against unauthorized access and ensure that sensitive data remains secure as it traverses the network.

Management and monitoring of the 24S are streamlined through its user-friendly interface. The switch supports a range of management protocols, including SNMP, RMON, and Web-based management, enabling network administrators to easily configure and monitor the system for optimal performance.

In summary, Accton Technology's 24S is a feature-rich Ethernet switch that combines high performance, scalability, and robust security features. With its advanced switching capabilities, redundancy options, and intuitive management tools, the 24S is well-equipped to meet the evolving needs of modern networking, ensuring businesses can operate efficiently and securely in an increasingly digital world. Whether for enterprise applications or data center operations, the 24S represents a significant advancement in networking technology.