Troubleshooting
If you experience any problems with the module, check the following items before
contacting Accton Technical Support:
Ensure the switch with the fiber optic module is powered up.
Ensure that the device attached to the module is powered up and operating correctly.
Ensure that the module is properly seated in the slot.
Verify that the module port is configured to match the communication mode used
by the attached device (full or half duplex).
Check the connectors on both ends of the cable to be sure they are properly
engaged. When attaching fiber cable to an SC-type port, be sure the plug clicks
into place to ensure that it is properly seated.
If you are using fiber optic cable with an ST-type connector (in conjunction with the
SC-ST converter*), try switching the TX and RX connectors.
Be sure the fiber terminators are clean. You can clean the cable plugs by wiping
them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty
fiber terminators on fiber optic cables will impair the quality of the light transmitted
through the cable.
* You may use the Cheetah ST Converter (Part Num ber: ST5002) to attach 62.5/
125 micron fiber cable with an ST-type connector to the SC-type port on the fiber
optic module.
Product Specifications
Access Method CSMA/CD
Ports 1 10000BASE-LX
Network Interface SC connector:
62.5/125 or 50/125 micron multimode fiber cable
9/125 micron single-mode fiber cable
Communication Mode Full or half duplex,
auto-negotiation for duplex mode and flow control
Size 12.25 x 90.70.5 x 2.74 cm (4.82 x 3.57 x 1.08 in.)
Power Consumption 2.4 W maximum
Temperature Operating: 0 to 50°C (32 to 122°F)
Storage: -40 to 158°C (-40 to 70°F)
Humidity 5% to 95%
Standards IEEE 802.3z Gigabit Ethernet
ISO/IEC 8802-3
Compliances CE Mark
Emissions FCC Class A
VCCI Class A
Industry Canada Class A
EN55022 (CISPR 22) Class A
C-Tick - AS/NZS 3548 (1995) Class A
Immunity IEC 1000-4-2/3/4/6
Warranty Three years