12-13

The time stored in the memory can be recalled even while the stopwatch is measuring.

 

With each press of “C”

 

 

When the stopwatch is stopped

Split time and lap time are recalled

 

starting with the first ones.

 

 

When the stopwatch is measuring

The times are recalled starting with

 

the last ones.

 

 

• To measure the lap time and split time while the stored data are being

recalled operate the buttons as follows.

B

A

Press “B” to measure new lap time and split time.

Press “A” to stop the measurement.

Press “D” to return to the measurement mode.

Notes:

1.Even if the digits are reset to “00”, stored times are not erased and can be recalled by pressing “C” unless new measurement is started.

2.If the stopwatch is left untouched with the recalled times shown, the display

will automatically return the STOPWATCH display in 1 to 20 minutes.

12

STOKE/FREQUENCY MEASURING

Press “D” to show the STROKE/FREQUENCY MEASURING display.

Start the measurement by pressing “A” and stop the measurement by pressing “A” after the third stroke was made. The number of strokes per minute will be displayed.

 

Start

Measuring

Stop

 

Reset

B

A

 

 

A

B

 

Start

 

Stop

STROKE/

 

 

 

The number

FREQUENCY

 

 

 

of strokes

MEASURING

 

 

 

per minute

mode

 

 

(23.2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

14-15

Notes:

1.During 1 second after the measurement has been started by pressing “A”, flashing “180.0” is displayed. If the measurement is stopped by pressing “A” during this period, “Err” will appear. If the measurement is not stopped by pressing “A” after more than 18 seconds have elapsed, “Err” will automatically appear. Therefore, note that measurable number of strokes per minute is between 10 and 180.

Error

REGISTER NOW Please return Email (preferred)

 

 

your AX602FY Registration to

User

 

the Repair Center address in the

 

 

 

 

 

 

warranty, and we will let you

 

 

 

 

 

 

 

 

 

 

know about future products.

 

 

 

 

 

 

 

 

 

 

 

NO-PROOF-OF-PURCHASE LIMITED WARRANTY

See label on back of unit for details, or check

http://support.ACCUSPLIT.com

2.If “B” is pressed while the measurement is stopped or “Err” is shown, the digits will be reset “0.0”. Even if the digits are not reset to “0.0” with the measurement stopped or “Err” shown on the display, the measurement can be started by pressing “A”.

14

15

Page 4
Image 4
Accusplit 980-312, AX602FY 12-13, 14-15, Recalled operate the buttons as follows, STOKE/FREQUENCY Measuring