Figure 16 - Removing the Spark Plug

Figure 17 - Measuring the Spark Plug Gap

Emptying the Fuel Tank

To store this generator for extended time, drain the gasoline from the fuel tank.

To drain gasoline from this generator:

1.Turn the fuel valve to the “off” position.

2.Remove the fuel filter cup. (See “Fuel Filter Cup Cleaning” earlier in this section.)

3.Empty the fuel filter cup of any fuel.

4.Place a receptacle underneath this generator to catch gasoline as it drains.

5.Turn the fuel valve to the “on” position and allow all gasoline to drain.

6.Turn the fuel valve to the “off” position.

7.Replace the fuel filter cup.

8.Store the drained gasoline in a suitable place.

Do not store gasoline for more than 3 months.

STORAGE/TRANSPORT PROCEDURES

Never place any type of storage cover on this generator while it is still hot.

When transporting or storing this generator for extended time:

Allow generator to fully cool before moving it. A hot engine and exhaust system can burn you and ignite some materials.

Disconnect the battery used for the electric start feature of this generator, first disconnecting the black cable and then the red cable.

Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.)

Turn the fuel valve to the “off” position.

Disconnect the spark plug. (See Figure 16, Removing the spark plug.)

Do not obstruct any ventilation openings.

Do not drop or strike this generator while moving it.

Store this generator in a cool dry area, free of excessive dust.

Storage Time

Less than 1 month

1 to 2 months

2 months to 1 year

1 year or more

Recommended Storage Procedure (which will help prevent difficult starts) No storage procedure required.

Fill with fresh gasoline and add gasoline conditioner

Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.) Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.) Disconnect the spark plug. (See Figure 16, Removing the spark plug.)

Model AC-G0004 5500 Surge Watts / 5000 Running Watts Electric Start Portable Generator